Accuracy, 200mV, 2, 20V ranges
15/16XL: ±(1% Rdg + 4 dgt)
Accuracy, 200V range
5XL: ±(1.2%Rdg + 10 dgt)
10/15/16XL: ±(1%Rdg + 4 dgt)
Accuracy, 500/600/750V ranges
5XL: ±(1.2%Rdg + 10 dgt)
10/15/16XL: ±(1.5%Rdg + 4 dgt)
Input Impedance
5XL: 450kΩ; 10XL: 4.5MΩ
15/16XL: 10MΩ
OL Protection, all rgs, exc. 200mV
5XL: 500VDC or AC RMS
10/15XL: 750VAC RMS/1000VDC
16XL: 600VDC or AC RMS
OL Protection, 200mV range, 15/
16XL: 350VAC/500VDC - 30 sec.
DC Current – Ranges
5XL: 200µA, 2, 20, 200mA
10/15XL: 200µA, 2, 20, 200mA,
10A; 16XL: 20, 200mA, 10A
Accuracy, 200µA 200mA ranges
5XL: ±(1.2% Rdg + 1 dgt)
10/15/16XL: ±(1% Rdg + 1 dgt)
Accuracy, 10A range
10/15/16XL: ±(2%Rdg + 3 dgt)
OL Protection, fast blow ceramic
fuse: 200mA input: 0.5A/250V
10A input: 10A/600V
AC Current (50-500Hz) – Ranges:
15XL: 200µA, 2, 20, 200mA, 10A
16XL: 20, 200mA, 10A
Accuracy, 200µA, 2, 20, 200mA rgs
15XL: ±(1.5% Rdg + 4 dgt)
16XL: ±(2% Rdg + 4 dgt)
Accuracy, 10A range
15/16XL: ±(2.5%Rdg + 4 dgt)
OL Protection, fast blow ceramic
fuse: 200mA input: 0.5A/250V
10A input: 10A/600V
Resistance – :Ranges
5XL: 200Ω, 2, 20, 200, 2000kΩ
10XL: 200Ω, 2, 20, 200, 2000kΩ,
20MΩ
15XL: 200Ω, 2, 20, 200, 2000kΩ,
20, 2000MΩ
16XL: 200Ω, 2, 20, 200kΩ, 2, 20MΩ
Accuracy, 200Ω ranges
5/10/15/16XL: ±(1% Rdg + 3 dgt)
Accuracy, 2k to 2MΩ ranges
5XL: ±(1.2%Rdg + 2 dgt)
10/15/16XL: ±(1%Rdg + 1 dgt)
Accuracy, 20MΩ range
10/15/16XL: ±(3%Rdg + 1 dgt)
Accuracy, 2000MΩ range
15XL: ±(5%Rdg -10 dgt) +10dgt
OL Protection, all ranges: 500VDC or
AC RMS
Open Circuit Voltage: 0.3VDC,
3.0VDC on 200Ω and 2000MΩ
ranges
Diode Test
Test Current: 1mA (approx.)
Test Voltage: 3.2VDC
Display: Forward Junction Voltage
Continuity
Audible Indication: at R ≤ 75Ω
OL Protection: 500VDC or AC RMS
Safety Tester™ (10XL)
Overload Protection: 350VAC RMS
for one hour, 350VDC for 30 s
Frequency Range: 50 to 60Hz
Capacitance (16XL)
Ranges: 2nF, 20nF, 200nF, 2µF, 20µF
Accuracy, all rgs: ±(3.5% rdg + 4 dgt)
Test Frequency: 400Hz
Frequency Counter (16XL)
Ranges (autoranging): 2kHz, 20kHz,
200kHz, 2MHz, 15MHz
Accuracy: ±(0.1% of rdg + 2 dgt)
– 29 –