Descargar Imprimir esta página

RIDGID GP80150RT Manual Del Operador página 19

Compresor de aire portátil de 30,3 litros (8 galones)

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
 Turn the belt tensioner bolt clockwise to move the engine
away from the pump until there is tension in the belt.
 Check belt alignment by placing a straight edge across
the front of the large and small pulley as shown in figures
32 and 33. The straight edge should touch the rim of the
large pulley at two places. When viewed from above, the
belt should be parallel with the straight edge.
NOTE: If the belt is misaligned, move the engine toward
or away from the air tanks.
 Check belt tension by squeezing the belt. Using light
pressure, the belt should deflect approximately 1/2 in.
NOTE: If belt tension is not correct, move the engine
toward or away from the pump.
 Once belt tension and belt alignment are correct, retighten
engine bolts and nuts.
 Reinstall the belt guard and secure with nuts, washers
and bolts.
 Replace the removable tank.
STORING THE AIR COMPRESSOR
Store the air compressor with the gas tank empty by running
the air compressor until the gas runs out. Allow 30 minutes
of "cool down" time before storing the machine. Store in a
dry, covered area where the weather can't damage it.
Air Compressor Tanks:
 Release all air from the air tanks.
 Drain all moisture from the air tanks, then close drain
valves.
PERIODIC MAINTENANCE SCHEDULE TABLE
NOTE: If a separate engine manual is provided for this air compressor, please follow the maintenance schedule provided
in the engine manual instead of the maintenance information listed below.
Maintenance Items
Check pump oil level
Check engine oil level
Check for oil leaks - inspect oil seals,
drain plug, oil plug, sight glass
Change pump oil
Change engine oil
Check/clean engine and pump air
filters
Discharge Fuel:
Drain the fuel tank completely by running the air compressor
until the gas runs out. Stored gas can go stale in 30 days.
Engine Oil:
Drain the oil and replace with fresh, clean oil.
Spark Plug:
 Disconnect spark plug wire and remove the spark plug.
Pour about a teaspoon of clean, air-cooled, four-cycle oil
through the spark plug hole into the combustion chamber.
 Leaving the spark plug out, pull the starter cord two or
three times to coat the inside of the cylinder wall.
 Inspect the spark plug and clean or replace, as necessary.
 Reinstall the spark plug, but leave the spark plug wire
disconnected.
Air Filter:
Clean the air filter.
PREPARING FOR USE AFTER STORAGE
 Pull the recoil starter three or four times to clean oil from
the combustion chamber.
 Remove spark plug from the cylinder. Wipe oil from the
spark plug and return it to the cylinder.
 Reconnect the spark plug wire.
 Refuel the machine as described earlier in the operator's
manual.
Before each use
X
X
X
19 – English
After first 20 hours
X
After every 100 hours
X
X
X

Publicidad