7.5 OTHER FUNCTION AND ALARM SIGNAL
7.5.1 AUTOMATIC PUMP DEHUMIDIFICATION CYCLE
× 5
Seconds.
Connect the machine, then press the VAC key for 5 seconds and close the lid. Wait until the end of the cycle.
It allows to pull out the steam that forms inside the pump due to the machine use. The duration is 20 minutes.
It is recommended to run it at least once a week, after a machine long inactivity and any time the pump has
to work hard (vacuum of liquid or not really cold products).
7.5.2 VACUUM SENSOR CALIBRATION
× 5
Seconds.
In order to calibrate the vacuum sensor to the atmospheric pressure level, at the first use and any time the
machine is moved from a place to another at a different altitude, it's necessary to operate the vacuum sensor
calibration. Connect the machine, then press the PUMP key for 5 seconds and close the lid. Wait until the
end of the cycle.
7.5.3 ACTIVATION/ DEACTIVATION OF ACOUSTIC SIGNAL
× 5
Seconds.
It is activated/deactivated by pressing the SEAL key for 5 seconds.
.
7.5.4 TEMPORARY BLACK-OUT
In case a temporary black-out occurs during a vacuum cycle, as soon as the power supply is restored, the vacuum chamber
is decompressed, the machine is on and comes back to the factory settings of vacuum and sealing.
7.5.5 INSUFFICIENT VACUUM ALERT
In case the minimum 500 millibar vacuum cannot be reached in 30 seconds, the vacuum packing machine stops the cycle.
All LED flash together with an acoustic signal.
7.5.6 OIL CHANGE ALARM
In order to avoid any damage to the pump, the machine records all the run cycles and help the user to remember when
it's time to change the oil through a visual and acoustic signal that activates every time the machine is turned on (once
the number of allowed vacuum cycles has been exceeded).
The technician will proceed to the oil change and to reset the alarm.
Rev. 02 - 05/2016 - Cod. 1500015 - Instruction manual for vacuum chamber packaging machines EVOX 25 / EVOX 25 H