MAINTENANCE
11.5 REPLACEMENT OF PUMP SHUTTER
(EVOX 25H - PUMP 8 MC/H)
1) To reach the pump for maintenance, follow the procedure descri-
bed at points from 3 to 6 in chap. 11.3
2) Locate the pump intake block on which is fastened the tran-
sparent pipe with metal coil
vacuum chamber.
3) Using a setscrew wrench to undo the two screw fasteners on the
block. Lift the intake block (Fig. 1).
4) Remove first the rubber shutter and then the steel one. Check the
condition of the accessible intake section and clean it if necessary
with a cloth soaked in alcohol (Fig. 2).
5) Put in the new rubber and steel shutters (Fig. 3).
6) Put the intake block back in place and fasten the two screws (Fig. 1).
7) Down and close the machine as described in chap. 11.3
46
Rev. 02 - 05/2016 - Cod. 1500015 - Instruction manual for vacuum chamber packaging machines EVOX 25 / EVOX 25 H