10. INSTALLATION
Operate following the instructions from 1 to 9:
1) Verify the working conditions: room temperature and air change. The room temperature of working place must
be between 10°C to 35°C. In the working place, a suitable air change must be ensured.
2) Machine unpacking (see cap. 4).
ATTENTION!
• After having removed the packaging, check the integrity of the machine. If in doubt, do not use the
machine and contact the dealer immediately.
• Never tilt or turn the machine over: always move it in the upright position. This prevents the oil leaking from
the vacuum pump.
• Only use man power with utmost care to move the machine.
ECOLOGICAL NOTES:
All of the various packaging components must be disposed of according to the Standards in force in
the Country where the appliance is used. In all cases, nothing must be dispersed into the environment.
WARNING!
• The packaging components can be potentially dangerous for children and animals, make sure that
they are kept out of their reach!
• The machines must be installed and inspected in complete respect with the Accident-prevention Standards, the
traditional legislation and Standards in force.
3) Verify the data plate. Always cite the model and serial number of the machine (see section 1.4) in order for us to
ensure efficient support and to best answer your questions. There is an identification plate on the back of the machine
bearing the following information:
A
Model.
b
Voltage and number of phases (Volt).
Frequency (Hertz).
C
D
Maximum power consumption (Watt).
E
Weight.
F
Year of manufacture.
G
Serial number.
4) Place the machine on a surface that is flat, stable and suitable for the load.
ATTENTION!
• The machine must be positioned so as to be accessible from all sides.
• Do not obstruct passage-ways, escape or service routes with the machine. Do not position the machine
in front of exits or emergency doors.
• Make sure the machine is ventilated properly, leaving a gap of about 10 cm around the entire appliance.
The ventilation slots must remain free and unobstructed in order to maintain the pump temperature at a normal
level.
Rev. 02 - 05/2016 - Cod. 1500015 - Instruction manual for vacuum chamber packaging machines EVOX 25 / EVOX 25 H
Via dell'Artigianato, 30 - 30024 MUSILE DI PIAVE (VE)
TEL.: 0039/0421/339030 - FAX: 0039/0421/334471
A
Type:
Voltage:
b
Frequency:
Power:
C
Mass:
D
E
INSTALLATION
ORVED S.p.A.
con Socio Unico
Year:
V
HZ
F
W
Serial no.
Kg
G
39