MAINTENANCE
11. MAINTENANCE
ATTENTION!
• Do not replace the Teflon when the bar is still hot because you could burn yourself.
• Always unplug the appliance before carrying out any maintenance.
11.1 REPLACEMENT OF COMPLETE SEALING BAR
• Extract the sealing bar from the vacuum chamber by lifting it horizontally from the sides (Fig. 1).
• Place the new one, making sure it engages correctly with the electrical contacts
Fig. 1
11.2 REPLACEMENT OF SEALING BAR TEFLON COVER
1) Extract the sealing bar from the vacuum chamber by lifting it horizontally from the sides (Fig. 1).
2) Remove the Teflon covering (Fig. 2).
42
Rev. 02 - 05/2016 - Cod. 1500015 - Instruction manual for vacuum chamber packaging machines EVOX 25 / EVOX 25 H
Fig. 2
A
.
A