3) Clean the sealing bar carefully using a cloth soaked in alcohol
(Fig. 3).
4) Put on the new Teflon covering, cutting off any excess at the
ends (Fig. 4).
5) Put the sealing bar back in the vacuum chamber, making sure
it engages correctly with the electrical contacts (Fig. 5).
Fig. 5
11.3 REPLACEMENT OF PUMP OIL
1) Run the pump for about 10 minutes in Jar function (pressing
PUMP key) to make the oil fluid.
2) Press STOP button to stop the pump.
3) Remove the plug.
4) Remove the PE fillers from the vacuum chamber (Fig. 6).
5) Uninstall the back panel. Unscrew the screws using a setscrew
wrench (Fig. 7-8).
Fig. 7
Rev. 02 - 05/2016 - Cod. 1500015 - Instruction manual for vacuum chamber packaging machines EVOX 25 / EVOX 25 H
MAINTENANCE
Fig. 3
Fig. 4
Fig. 6
Fig. 8