Specifications
Display: LCD (5000) and 52-segment bar graph
Polarity: Automatic
Sampling Rate:
Numeric Display: 5 per second
Bar Graph Display: 60 per second
Temperature Coefficient: Nominal 0.15 x (specified accuracy) per °C
below 18 °C or above 28 °C
Automatic Power-Off: After 17 minutes of inactivity.
To disable this feature, press RANGE while turning the meter on.
Noise Rejection*:
Normal Mode Rejection Ratio > 60 dB at 50 Hz and 60 Hz when measuring DCV
Common Mode Rejection Ratio > 60 dB from 0 Hz to 60 Hz when measuring ACV
Common Mode Rejection Ratio > 120 dB at 0 Hz, 50 Hz and 60 Hz when measuring DCV
Operating Conditions:
0 °C to 35 °C (32 °F to 95 °F), 0% to 80% relative humidity (non-condensing)
35 °C to 40 °C (95 °F to 104 °F), 0% to 70% relative humidity (non-condensing)
Altitude: 2000 m (6500') maximum
Indoor use only
Storage Conditions: –20 °C to 60 °C (–4 °F to 140 °F)
0% to 80% relative humidity (non-condensing)
Remove battery.
Battery: 9-Volt (NEDA 1604, JIS 006P or IEC 6F22)
Pollution Degree: 2
Overload Protections:
Volts: 1050 V RMS, 1450 V peak
Millivolts: 1050 V RMS, 1450 V peak
A: 15 A/1000 V fuse, interrupting rating 10 kA, 13/32" x 1-1/2"
µA and mA: 1 A/600 V fuse, interrupting rating 100 kA, 13/32" x 1-1/2"
Other Functions: 1050 V RMS, 1450 V peak