SEcTIoN 2
2.3
Plumbing Box Installation
WaRNINg
caUTIoN
See appropriate equipment literature for operating conditions and necessary gas purities .
caUTIoN
gas Purging:
When switching between H-35 and an oxidizing gas (air or oxygen) it is recommended that the following procedure be
followed:
1 .
Turn off the gas .
2 .
Put the system into plasma gas test until line pressure is exhausted . If the start gas is being switched to or from
H-35, switch to start gas test until that line is exhausted as well .
3 .
Disconnect the old gas and connect a relatively inert gas such as nitrogen, argon, carbon dioxide, C-25, etc . Set the
pressure to 50 psig (3 .5 bar) and purge each affected line for 60 seconds .
4 .
Then shut off the gas and exhaust each line per Step 2 .
5 .
Connect the gas to be used . Set the pressure to recommended values for the cutting condition to be used, and
purge each affected line for 15 seconds per 25 ft . (7 .6 m) of line .
ElEcTRIcITY caN KIll!
HIgH VolTagE caN BE PRESENT BEHIND coVER PlaTE. Do NoT oP-
ERaTE WITHoUT coVER PlaTE IN PlacE. BEFoRE REMoVINg coVER
PlaTE oR PERFoRMINg aNY MaINTENaNcE oR aSSEMBlY oF THIS
EqUIPMENT, ENSURE THE PoWER SoURcE IS TURNED oFF aND DIS-
coNNEcTED.
only qualified maintenance personnel should repair and maintain
this equipment.
Unit is NoT designed for use in rain or snow. Damage to equipment
may result.
Unit is to be lifted only by the handle provided . Failure to do so may
result in damage to the equipment.
Flashback a rrestors a re r equired t o p revent fi re f rom p ropagating b ack
to the gas supply through lines carrying oxygen or fuel gases.
Use aWg 1/0 power cable to carry electrode current from the power
source to the Pcc-14. See Table 2-2 for additional cables.
avoid using the same supply lines for both oxygen and air if oil may
be mixed with the air. oil in the presence of 100% oxygen can be
highly flammable.
Failure to observe above cautions may result in personal injury and /
or damage to the equipment.
The expected life of the internal flexible hoses is 10 years .
Replace them earlier if cracking or brittleness is noted .
DEScRIPTIoN / INSTallaTIoN
Note:
Note:
13