10.2
Cleaning the dirt trap
Cleaning the dirt trap
The dirt trap in the degassing pipe must be cleaned no later than after the expiry of the continuous degassing time. Check the dirt
traps after every filling action or extended operation.
1.
Press 'Stop' on the controller's operator panel.
–
The device is non-functioning and the vacuum pump
is shut down.
2.
Close the ball valve (1) upstream of the dirt trap (2).
3.
Slowly unscrew the cap with the sieve.
–
The residual pressure in the pipe segment is
released.
4.
Pull the sieve out of the cap.
5.
Clean the sieve with a soft brush and rinse it with clear
water.
6.
Check the seal for damage and replace as necessary.
7.
Insert the sieve in the cap and turn the cap with the sieve in the housing of the dirt trap (2).
8.
Open the ball valve (1) upstream of the dirt trap (2).
9.
Press 'Auto' on the controller's operator panel.
–
The device is switched on and the vacuum pump is in operation.
10.3
Maintenance certificate
All maintenance tasks have been completed according to the Reflex Installation, Operating and Maintenance Manual.
Date
11
Removal
DANGER
Risk of serious injury or death due to electric shock.
If live parts are touched, there is risk of life-threatening injuries.
•
Ensure that the system is voltage-free before installing the device.
•
Ensure that the system is secured and cannot be reactivated by other persons.
•
Ensure that installation work for the electric connection of the device is carried out by an electrician, and in compliance
with electrical engineering regulations.
CAUTION
Risk of burns
Escaping hot medium can cause burns.
•
Maintain a sufficient distance from the escaping medium.
•
Wear suitable personal protective equipment (safety gloves and goggles).
Service organisation
Vacuum spray degassing — 20.05.2019
Signature
Removal
Remarks
English — 27