Mounting The Water Drain Outlet (Optional) - Dometic CRX 50 Instrucciones De Montaje

Nevera con compresor
Ocultar thumbs Ver también para CRX 50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
Installing and connecting the refrigerator
Observe the following when installing the refrigerator:
• Install the refrigerator so that the warm air produced can easily flow away
(either upwards or to the sides, fig. 8, page 7).
Key to fig. 8, page 7
No.
Explanation
1
Cold intake air
2
Hot waste air
3
Condenser
4
Spacing above the refrigerator if there is not sufficient air to circulate
above or at the side.
• Observe the following installation dimensions:
Model
CRX50
CRX65
CRX80
CRX110
CRX140
• Keep objects clear of openings in the housing or installation structure (such as
ventilation slots, etc.).
• Condensate is produced when the refrigerator is operating normally. You can
either wipe up the condensate on the floor of the refrigerator in regular intervals,
or drain it through an outlet in the floor of the refrigerator (see chapter "Mounting
the water drain outlet (optional)" on page 22).
7.3

Mounting the water drain outlet (optional)

➤ Connect a hose with an inside diameter of 10 mm (not included) to the water
drain outlet.
➤ Lay the refrigerator on its side in order to access the bottom side.
➤ Mount the water drain outlet (fig. 9 2, page 8) aligned to the front or to the
back according to the desired outlet direction.
➤ Remove the water drain plug (fig. 9 1, page 8) inside the refrigerator.
22
Dimensions W x H x D (mm)
390 x 544 x 550
458 x 535 x 595
485 x 650 x 578
530 x 755 x 608
550 x 825 x 670
CRX