System Lay-Out; Technical Features - RIB K500 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SYSTEM LAY-OUT

1 - K500 operating device
2 - External photocells
3 - Rack of Module 4
4 - Key selector
5 - Radio antenna
6 - Blinker
7 - Limit switch plate (cams)
8 - Mechanical strip
9 - Pneumatic strip or Fotocosta
10 - Internal Photocells
11 - Photocell columns
12 - Mechanical stops

TECHNICAL FEATURES

Irreversible operating devices for sliding gates with a maximum weight of
500 kg / 4900 lbs.
The irreversibility of this operating device allows you to avoid using any electric lock
for an effective closing of the gate. The motor is protected by an heat probe, that
temporary interrupts the operating cycle in case of prolonged use.
Measurements in mm/inch
TECHNICAL
DATA
Max. leaf weight
Rack
EEC Power supply
Thrust force with constant turns
Max torque
Motor capacity
Power absorbed
Capacitor
Power supply 120V
Thrust force with constant turns
Max torque
Motor capacity
Power absorbed
Capacitor
Normative cycles 230V/50Hz
Normative cycles 220V/60Hz
Normative cycles 120V/60Hz
Daily operations suggested
Service
Guaranteed consecutive cycles
Grease
Weight of electroreducer
Noise
Working temperature
Protection
25
K500
kg
500
4
230V~ 50Hz
230V~ 60Hz
N
400
Nm
9,5
W
229
A
1,21
µF
10
120V~ 60Hz
N
500
Nm
12
W
259
A
3,5
µF
35
12 - 30s/2s
10 - 30s/2s
9 - 30s/2s
300
60%
25/5m
COMLUBE LHITGREASE EP/GR.2
kg
8
db
<70
°C
-10 ÷ +55
IP
54
G
B
1
228
1,05

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K500 serieAa33694Aa33695Aa33753wAa33693Aa33696

Tabla de contenido