mENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands have
IBL
no effect during the opening phase.
Off: multi-flat function disabled.
During the TCA phase, the PP controls are enabled or disabled.
IBCA
On: PP controls are disabled.
Off: PP controls are enabled.
The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes the
automatic closure after 3 s.
SCL
If the photocell is activated during the opening phase, the operation is completed
and closure starts after 3s
Off: disabled rapid closure.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the
PRE
starting of the motor.
Off: disabled forewarning flashing light.
The Service Man function is enabled or disabled.
On: Service Man operation. The OPEN/CLOSE push buttons should be kept
HTR
pressed for the entire operating time.
Off: Automatic operation.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Enables blinker.
Off: Disables blinker.
The Encoder is enabled or disabled.
On: Activated Encoder.
ENC
Off: Not activated Encoder. The encoder only detects the door/gate stroke. In the
event of maintenance operations, it is advisable to deactivate it only temporarily.
The PHOT 1 input is enabled or disabled in the opening phase.
Pho1
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
Pho2
As per PH01, but referred to PHOT 2 input.
Pho3
As per PH01, but referred to PHOT 3 input.
Pho4
As per PH01, but referred to PHOT 4 input.
The check on the photocell connected to PHOT1 input is activated or deactivated
Before operation, the control unit checks the switching of the photocell contact.
tst1
If the checks are not successful, the door/gate will not move.
On: activated check on photocell.
Off: deactivated check on photocell.
tst2
As for TST1, but referred to PHOT2 input
tst3
As for TST1, but referred to PHOT3 input
tst4
As for TST1, but referred to PHOT$ input
The opening direction of the motor is selected (see Fig. 4):
MINV
On: Right side motor mount
Off: Left side motor mount
LOGIC (LOG)
FUNCTION
mEmO
ON-OFF-(Default)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
19