It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once the password
is typed in, it is possible to act on the control unit by entering and exiting the programming mode for around 10 minutes in order to
allow adjustments and tests on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access to any other
menu. If a protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
If the code corresponds to the previous one, a confirmation message "OK" appears.
The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protection code must be
ImPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance
typed in.
operations. To remove the code from a protected control unit, enter the programming mode with the password
and reset the code to the 0000 default value.
IF YOU LOOSE THE CODE, PLEASE CONTACT THE AUTHORISED SERVICE CENTER FOR THE TOTAL RESET OF
THE CONTROL UNIT.
TABLE 1
FSTS
Speed
Value
(m/min)
30
35
40
45 (DEFAULT)
50
55
60
65
70
75
80
85
90
The door/gate stroke is shown in the following scheme:
The V axis is the gate/door speed, T axis is the time required by the door/gate to move from a limit switch to the other. The parameters
govern both the opening and the closing phases.
At gate/door stopped on any SWO (SWC) limit switch, when a control key is pressed the gate/good starts moving and reaches the
standard operating speed, which can be adjusted by FSTS parameter.
The TACC time sets how rapidly the gate/door should reach the standard speed.
Before meeting the SWX (SWO) stop limit switch, braking preset by TSM time will start.
Braking leads the gate/door from standard speed (FSTS) to braking speed, adjusted by SLDS parameter.
The TDEC time sets how rapidly the gate/door should reach the braking speed.
PASSWORD (CODE)
Recommended values
TBR
7
3
8
3
9
3
10
3
11
3
12
4
13
5
14
6
15
7
16
8
17
9
18
10
19
10
HOW TO ADJUST SPEED AND BRAKING
V
SWO (SWC)
TAcc
TDEC
TSM
50
10
50
10
50
10
50
10
60
12
65
13
70
13
80
14
85
15
89
16
93
17
96
19
99
20
FSTS
Tdec
TSM
Leaf max. weight (kg)
BISON 25
BISON 30
2500
3000
2500
3000
2500
3000
2500
3000
2000
2400
1700
2050
1450
1750
1250
1500
1100
1300
950
1150
850
1000
750
900
650
750
SWC (SWO)
slds
T
BLC
BISON 45
4500
4500
4500
4500
3600
3050
2600
2250
2000
1700
1500
1350
1150