Spare Parts And Accessories - Aventics EV12 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
AVENTICS | EV12/EV18 | R414011404–BAL–001–AA | English
Table 16:
Pneumatic data EV18 pressure regulator
Pneumatics
p-Range
0...10 bar
Flow at P
16500 l/min
max
Reproducibility
< 80 mbar
Hysteresis
< 120 mbar
Table 17:
Electronics data
Electronics
Connections
M12 connection, 5-pin, A-coded
Power supply
24 V DC (+30%/−20%)
Only use the following power supply for the components:
W
24 V DC PELV power circuits in accordance with DIN EN 60204-1/IEC 60204-1:
The PELV power source must be a safety isolation transformer in accordance with
IEC 61558-1 or IEC 61558-2-6, or a power source offering the same degree of
safety as a safety isolation transformer.
O Make sure that the power supply of the power pack is always less than
300 V AC (outer cable – neutral wire).
Max. current consumption
220 mA
Permissible harmonic
5%
content
Response to power failure
Hold last pressure value
Variant 0–10 V
Voltage input resistance (set
Power supply switched on: 1 MΩ
point)
Power supply switched off: high-ohmic
External ohmic load (voltage
> 10 kΩ
output/actual value)
Switch output
Voltage:
Switch output = power supply 1.8 V
Variant 4–20 mA and 0–20 mA
Current input resistance (set
Power supply switched on: 100 Ω
point)
Power supply switched off: high-ohmic
External ohmic load (current
< 300 Ω
output/actual value)
Switch output
Current:
Short-circuit-resistant, max. 1.4 A
IO-Link variant
Control
IO-Link
IO-Link version
1.1 (compatible with 1.0)
Baud rate
COM2: 38.4 kBit/s
Cycle time
5 ms at 38.4 kBit/s
Operating Mode
IO-Link mode, no standard IO mode
Port type
Port class A (type A)
Table 18:
Standards
Standards complied with
EN 61000-6-2
Electromagnetic compatibility (EMC) – Part 6-2: generic
standards – interference immunity for industrial areas
EN 61000-6-4
Electromagnetic compatibility (EMC) – Part 6-4: generic
standards – interference emission for industrial areas
DIN EN ISO 4414 Pneumatic fluid power – General rules and safety
requirements for systems and their components

14 Spare Parts and Accessories

Information on spare parts and accessories can be found in the online catalog at
www.aventics.com/pneumatics-catalog.
22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ev18

Tabla de contenido