Service And Repairs; Conversion And Extension; Technical Data - Aventics CR1-OX Instrucciones De Servicio

Cartucho de válvula reguladora de presión
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
AVENTICS | CR1-OX | R414010019–BAL–001–AA | English
Assembly with aluminum base body
O Assemble the pressure regulator cartridge inline with
the base body at a suitable location in your pneumatic
system.
During commissioning
O Use is permitted only under the operating conditions
and within the performance limits listed in the

technical data.

O Check that all the electrical and pneumatic connections
are allocated or closed. Only commission fully installed
products.
1
Adjust pressure
1. Release the lock nut (B) by turning it once
counterclockwise.
2. Set the desired pressure by turning the regulating
screw (A).
3. Lock the regulating screw (A) again by firmly turning
the lock nut (B) clockwise.
Note: Medium flows from P
6

Service and Repairs

Cleaning and servicing
W
Close all openings with suitable safety devices so that
no cleaning agent can enter into the system.
W
Never use solvents or aggressive detergents.
Only clean the product using a slightly damp cloth.
Only use water and, if necessary, a mild detergent.
W
Do not use high-pressure cleaners for cleaning.
W
Do not use compressed air to clean (blow off) the
pressure regulator or the pneumatic system.
7
Decommissioning,
Disassembly, Replacement
Danger of injury in case of disassembly
or replacement under pressure or voltage
Disassembling or replacement when under pressure
or electrical voltage may lead to injuries and damage
to the product or system components.
O Make sure that the relevant system part is not under
voltage or pressure before you disassemble the
product or replace parts.
O Protect the system against being switched on.
2
1 to P
2
IN
OUT
CAUTION
8
Disposal
Dispose of the product, the packaging material,
and condensate in accordance with the national
regulations in your country.
9

Conversion and Extension

For extensions and conversions, please contact
AVENTICS service.
10 Technical Data
Maximum permissible pressure, temperature range,
and thread connection are indicated on the products.
General data
Max. input pressure
p-Range
Medium
Ambient
temperature
min./max.
Mounting
orientation
Mounting
Connection
IN (1)/OUT (2)
Exhaust
Further technical data can be found in our
online catalog at
www.aventics.com/pneumatics-catalog.
W
10 bar
W
0...0.5/0...2/0...3/0...4 bar
W
Oxygen, air, inert gases
W
-5°C/+50°C
W
Any
W
Pressure regulator cartridge
for a special seat in
a customer-specific pneumatic
system, Fig.
and
2
W
Inline with aluminum base body
W
G 1/8 (only with aluminum
base body)
W
None
6
3

Publicidad