USER'S MANUAL TV EXPLORER
5.11
Verification of distribution networks
(SAT IF Test / Attenuation Test)
This
application
(Telecommunications Common Infrastructures) before the antennas and head-end
devices are operative. The procedure allows the user to evaluate the frequency
response of a whole TV signals distribution network by means of two steps:
NOTE: For this application the use of PROMAX RP-050, RP-080, RP-110 or
RP-250 signal generators are required, for which they have been specially
designed. If you use a generator that emits not modulated carriers, this may
cause a slight uncalibration during the SAT IF TEST.
1.- CALIBRATION
Connect the generator directly to the TV EXPLORER
BNC-F adapter.
Power the signal generators of the RP PROMAX family through the
TV EXPLORER
HD
ISDB-T/T
function (see section '5.7 External Units Power Supply') press the
rotary selector
[1] to set a voltage of 13 V.
Finally, select the SAT IF TEST application on UTILITIES
band, or the ATTENUATION TEST for terrestrial band, connect the generator to the
point where the antenna will be connected (signal source).
Press the
[17] key to see on screen the measurement CONFIGURATION. By
means of the Threshold Attenuation option is possible to adjust the maximum difference
between the pilots reference level from 5 to 50 dBμV.
Later, by means of the horizontal cursors
(see the following figure). Wait for some seconds until the calibration process for three
pilots is completed: MEASURING REF. is indicated on screen while this process is in
progress.
10/2012
HD
ISDB-T/T
B
allows
the
user
to
or an external power supply. To set the External supply
B
verify
easily
the
TCI
HD
ISDB-T/T
[11] key, and the
[22] menu for SAT
[6] key, select the Calibrate function
features
using the
B
Page 39