MACHINE PROGRAMME
FOCUS TIG 200 AC/DC PFC is an air-cooled,
single-phased welding machine for MMA and
TIG welding.
Welding hoses
The machine can be equipped with
TIG welding hoses, electrode holders and
return current cables from the MIGATRONIC
programme.
Moreover, we can offer you the following:
Foot control

INITIAL OPERATION

Mains connection
The machine must be connected to a mains supply and
protection earthing. After the mains plug (1) has been
connected to the mains the machine is ready for use. Please
note that all cable connections must be made by authorised
and qualified staff. Switch on and off the machine by means of
the breaker (3) on the rear of the machine.

Configuration

MIGATRONIC disclaims all responsibility for damaged
cables and other damages related to welding with
undersized welding torches and welding cables measured
by welding specifications e.g. in relation to permissible load.
Generator use
This welding machine can be used at all mains supplies
providing sine-shaped current and voltage and not
exceeding the approved voltage tolerances stated in the
technical data. Motorised generators observing the above
can be used as mains supply. Consult your supplier of
generator prior to connecting your welding machine.
MIGATRONIC recommends use of a generator with
electronic regulator and supply of minimum 1.5 x the
maximum kVA consumption of the welding machine. The
guarantee does not cover damage caused by incorrect or
poor mains supply.
Dispose of the product according to local standards
and regulations.
www.migatronic.com/goto/weee

Important!

In order to avoid damage to plugs and
cables, good electric contact is required
when connecting the work return cable
and welding torch to the machine.
Gas connection
Connect the gas hose (2) to the gas system by means of a
gas pressure reducer with flow control. Fit and secure the gas
hose to the gas connection (6) on the front of the machine.