Initial Operation - Migatronic CAR-O-LINER CM Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Mains connection
It is important to ensure that the mains supply voltage
is in accordance with the voltage to which the machine
is built. If the machine can be adjusted for use on
several different voltages then the machine must be
checked to confirm that it has been set to the correct
voltage.
Connection of gas bottle
Use only gas bottles with a max. height of 100 cm. If
larger bottles are used the machine may tip over.
Configuration
CAR-O-LINER disclaims all responsibility for damaged
cables and other damages related to welding with
under sized welding torch and welding cables
measured by welding specifications e.g. in relation to
permissible load.
Important!
In order to avoid destruction of plugs
and cables, good electric contact is
required when connecting earth cable
and welding torch to the machine.
Adjustment of wire brake
The wire brake must ensure that the wire reel brakes
sufficiently quickly when welding stops. The required
brake force is depending on the weight of the wire reel
and the maximum wire feed speed. A brake torque of
1.5-2.0 Nm will be satisfactory for most applications.
Adjustment:
- Dismount the control knob by
placing a thin screw driver
behind the knob and
thereafter pull it out
- Adjust the wire brake by
fastening or loosening the
self-locking nut on the axle of
the wire hub
- Remount the knob by
pressing it back into the groove
INITIAL OPERATING
Generator use
This welding machine can be used at all mains
supplies providing sine-shaped current and voltage
and not exceeding the approved voltage tolerances
stated in the technical data. Motorised generators
observing the above can be used as mains supply.
Consult your supplier of generator prior to connecting
your welding machine. CAR-O-LINER recommends
use of a generator with electronic regulator and supply
of minimum 1.5 x the maximum kVA consumption of
the welding machine. The guarantee does not cover
damage caused by incorrect or poor mains supply.
12
Dispose of the product according to local
standards and regulations.