SEAS ONAL MAINTE NANCE
(implemented by the DEALER )
Consists in:
• Clean the boiler-stove internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber
and the relative compartment
• Clean fans, verify mechanical and clamp loosening
• Clean smoke channel (replace seals on smoke exhaust pipe)
• Clean smoke duct
• Check the expansion tank
• Clean/check the Synoptic Panel
• Clean smoke extraction fan compartment.
• Clean smoke check thermocouple.
• Empty the pellet hopper and clean the base with the vacuum
cleaner.
• Clean, inspect and scrape any residue from the ignition resistan-
ce compartment and if necessary, replace it
• Visually inspect the electrical wires, connections and power cable
• Check play of the screw-gear motor group
• Clean the pellet hopper and check loosening of the feed screw -
gear motor assembly
• Replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10
minutes and shutdown
If the boiler-stove is used very frequently, it is advisable to
clean the smoke channel and the fume duct every 3 months.
ATTENTION !!!
After implementing a normal cleaning procedure, INCOR-
RECT coupling of the upper (A) ( gura C) and lower
(B) ( gura C) combustion chambers can compromise the
stove's performance. Before igniting the stove, make sure
the combustion chambers are correctly paired as indicated
in ( g. D) without ash or unburnt material present on the
support perimeter.
We remind you that using the stove without cleaning the mel-
ting pot, may cause a sudden ignition gas inside the combu-
stion chamber with the consequent breaking of the glass
CLEANING THE SMOKE DUCT
• With the boiler stove off and cooled down, apply force to move
the cleaning rod (see previous page); remove the interlocking
sheet metal lower front panel (4 - Fig. E).
• Remove the sheet metal inspection panel (5 - Fig. E) together
with the silicone gasket (6 - Fig. E) secured with wing nuts; clean
the silicone gasket and aspirate the residues in the fume conduit
(7 - Fig. E).
The thermo stove comes with a spare silicone gasket.
The quantity of residue which forms depends on the type of fuel
and the type of system.
If cleaning is not carried out, the boiler-stove may not function
properly.
Note: after the operation, make sure that the smoke duct
inspection closure is correctly repositioned.
MAINTENANCE
fi g. C
fi g. D
fi g. E
- 54
-
6
5
4
B
A
7