Teaching In Switchpoint S2; Teach-In Error - Balluff BMF 203K-H- C-A-PU Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 109
BMF 203K-H- _ _ -C-A _ -... / BMF 235K-H- _ _ -C-A _ -...
Magnetic Field Sensors
5
Manual teaching of the switchpoints (continued)
5.2

Teaching in switchpoint S2

1. Retract the piston rod to the desired second position.
Fig. 5-5:
Retracting the piston rod
2. Press and hold the button.
⇒ The green LED begins to flash, indicating that
teach-in mode is active.
Fig. 5-6:
Green LED flashes
⇒ After 3 seconds, the yellow LED (switchpoint S1)
will also begin to flash.
Fig. 5-7:
Green and yellow LEDs flash
3. Continue holding the button until the orange LED
(switchpoint S2) flashes and the yellow LED goes out
after 6 seconds.
Fig. 5-8:
Green and orange LEDs flash
4. Release the button.
⇒ The sensor is now ready for teaching in the second
switchpoint.
5. Press the button once more briefly.
⇒ Switchpoint S2 is saved and the green LED is lit
constantly.
⇒ If the piston remains unchanged in position 2, the
yellow LED also lights up now. This means output
S2 is switched on.
Fig. 5-9:
Green and orange LEDs are on
www.balluff.com
5.3

Teach-in error

When attempting to teach in a piston position that is
outside of the detection area (insufficient magnetic field
strength), the yellow and orange LED flash alternately for 3
seconds after releasing the button.
In this case, the previously taught-in value of the
corresponding switchpoint is not overwritten, but remains
unchanged.
Fig. 5-10: Piston rod outside the detection area