18. Technical specifications

RME 339.0, RME 339.0 C
Serial number
6320
Type
Universal AC
motor
Voltage
230 V~
Power input
1200 W
Frequency
50 Hz
Fuse
5 A
Protection class
II
Type of protection
IPX 4
Cutting device
Cutter bars
Cutting width
37 cm
Speed of cutting
device
3200 rpm
Cutter bar drive
Permanent
Blade fastening
screw tightening
torque
10 - 15 Nm
Cutting height
30 - 70 mm
Cutting height (Great
Britain only)
20 - 70 mm
Grass catcher box
40 l
Wheel diameter
(front)
150 mm
Wheel diameter
(rear)
180 mm
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
93 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
79 dB(A)
pA
Uncertainty K
1 dB(A)
pA
0478 121 9919 A - EN
RME 339.0
Length
122 cm
Width
42 cm
Height
107 cm
Weight
14 kg
Weight (Great Brit-
ain only)
15 kg
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
0,82 m/sec
hw
Uncertainty K
0,41 m/sec
hw
Measurement in accordance with
EN 20643
RME 339.0 C
Length
135 cm
Width
43 cm
Height
110 cm
Weight
15 kg
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
0,50 m/sec
hw
Uncertainty K
0,25 m/sec
hw
Measurement in accordance with
EN 20643
18.1 REACH
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.
19. Troubleshooting
If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor does not start
Possible cause:
2
– No mains voltage
– Connection cable, plug, plug connector
2
or switch defective
– Start button not pressed
– Motor is overloaded because the grass
is too tall or too wet
– Motor overload protection activated
– Mower housing is blocked
– Fuse in plug faulty (GB version)
Remedy:
– Check fuse (
– Check cable/plug/switch and replace if
necessary (
11.1)
– Press start button (
– Do not switch on motor in high grass,
2
adapt cutting height (
2
– Allow machine to cool down (
– Clean mower housing (
– Replace fuse in plug ( )
Fault:
Frequently tripped mains fuse
Possible cause:
– Unsuitable electric cable
– Power overload
– Machine is overloaded due to mowing
grass which is too long or too wet
Remedy:
– Use suitable electric cable (
– Connect machine to another circuit
11.1)
11.3)
8.3)
9.5)
12.2)
11.1)
45