NOTE: For this application the use of PROMAX's RP-050 / RP-080 or RP-250
signal generators are required, for which they have been specially
designed.
1.- CALIBRATION
Connect the generator directly to the TV EXPLORER II / II+ using the BNC-F
adapter.
Power on the RP-050/RP-080 through the EXPLORER, for it is necessary to set
the External supply function (see section '5.7 External Units Power Supply') by
pressing the
[11] key, and the rotary selector [1] to set a voltage of 13 V.
Finally, select the SAT IF TEST application on UTILITIES
band, or the ATTENUATION TEST for terrestrial band, connect the generator to the
point where the antenna will be connected (signal source).
Press the
[17] key to see on screen the measurement CONFIGURATION.
By means of the Threshold Attenuation option is possible to adjust the maximum
difference between the pilots reference level from 5 to 50 dBμV.
Later, by means of the horizontal cursors
function (see the following figure). Wait for some seconds until the calibration process for
three pilots is completed:
MEASURING REF.
progress.
10
0
-10
-20
FREQ:
REF:
TEST:
ATT:
Figure 16.- SAT IF Test. Satellite band.
Page 38
USER'S MANUAL. TV EXPLORER II/II+
is indicated on screen while this process is in
1042.25
1703.25
2108.25
84.7
90.2
100.3
84.5
90.2
99.1
0.2
0.0
CALIBRATE
[22] menu for SAT
[6] key, select the Calibrate
MHz
dBuV
dBuV
1.2
dB
EXIT