Options – Pelvic restraint belt
Before using the wheelchair make
sure that the pelvic restraint belt is
fitted.
The pelvic restraint belt must be checked
on a daily basis to ensure it is free from any
obstruction or adverse wear.
Always make sure that the pelvic restraint
belt is correctly secured and adjusted prior to use. If the strap
is too loose, this could cause the user of the wheelchair to
slip down and risk suffocation or serious
injury.
The pelvic restraint belt is fitted to the
wheelchair as shown in the illustrations. The
seat belt comprises two halves. They are
fitted using the existing seat stay retaining
bolt fitted through the eyelet on the belt. The
belt is routed under the rear of the side panel.
(Fig. 28)
Adjust the belt position so buckles are in the centre of the seat.
(Fig. 29)
Adjust the pelvic restraint belt to suit the user's needs as
follows:
To reduce the belt
length
Feed free belt back
Feed free belt through slide adjusters and
through male buckle
male buckle to provide more belt length.
and slide adjusters.
Ensure belt is not
looped at male
buckle.
When fastened check space between the pelvic restraint belt and
user. When correctly adjusted it should not be possible to insert
more than the flat of the hand between the pelvic restraint belt and
the user. (Fig. 30)
Fig. 28
Fig. 29
To increase the belt length
Fig. 30
The pelvic restraint belt should be fixed so that
the belt sits at an angle of 45 degrees across
the user's pelvis. The user should be upright
and be as far back as possible in the seat when
correctly adjusted. The pelvic restraint belt
should not allow the user to slip down in the
seat.
(Fig. 31)
To fasten buckle:
Firmly push male buckle into
female buckle.
If you have any questions on the use and operation of
the pelvic restraint belt, the please contact your
wheelchair dealer, carer or attendant.
Notes for the patient
The pelvic restraint belt must only be fitted or adjusted by an
approved SunriseMedical dealer / agent. .
The pelvic restraint belt must be checked on a daily basis to ensure
it is adjusted correctly and free from any obstruction or adverse
wear.
Sunrise Medical does not recommend the transportation of a person
in a vehicle with the pelvic restraint belt as a restraint system. See
the transit brochure from Sunrise Medical for further information on
transportation.
Maintenance:
Check pelvic restraint belt, and securing components, at regular
intervals for any sign of frays or damage. Depending on usage, it
may need to be replaced.
NOTE:
The pelvic restraint belt should be adjusted to suit the end user as
detailed above Sunrise Medical also recommends that the length
and fit of the belt is checked on a regular basis to reduce the risk of
the end user inadvertently re-adjusting the belt to an excessive
length.
Options - Stabilising bar
Folding stabilising bar
This bar is used to stabilise the
backrest. To be able to fold the
wheelchair, the release lever must
be pushed inwards (Fig. 32) or
released and the stabilising must
be flipped downwards.
When unfolding the wheelchair,
please make sure that the stabilis-
ing bar is locked into position.
Fig. 31
To release belt:
Press exposed sides of male
buckle together at the same time
and push to the middle, while at
the same time pull them gently
apart.