Classeq Pass Through Range - User Manual
Caution
Damage to the
will NOT be covered by the Manufacturer's
Warranty, see Section 12.
7.4
Regular Maintenance
7.4.1
Water softener salt (if fitted)
When the salt level inside the Salt Reservoir gets low the Refill
Salt indicator will illuminate on the display.
The salt should be replenished as soon as possible to avoid
limescale from building up in the warewasher. To refill the Salt
Reservoir follow the instructions below:
1.
Fully open up the warewasher by lifting the Hood up.
2.
Remove the Basket Ramp.
3.
Remove the Salt Reservoir Cap at the front right hand
cornerof the Wash Chamber.
4.
Fill the Salt Reservoir with salt.
5.
Wipe away away any excess or spilt salt from the Salt
Reservoir and Wash Chamber.
6.
Refit the Salt Reservoir Cap, ensuring that the cap is
fitted flat and secure.
7.
Do not overtighten the Salt Reservoir Cap.
8.
Replace the Basket Ramp
9.
Fully close down the Hood to the warewasher.
10. Refill the warewasher and draindown to remove any
residual salt water after refilling the Salt Reservoir.
warewasher
caused by limescale
Note:
The Refill Salt indicator may stay illuminated for up to
three complete wash cycles after filling / refilling the Salt
Reservoir with salt.
Caution
DO NOT run the
in the Salt Reservoir, as this will allow limescale
to build up. Limescale deposits in the
warewasher
will invalidate the warranty.
Caution
DO NOT add any chemicals, such as detergent
or rinse aid to the Salt Reservoir. These will
cause damage to the warewasher.
Caution
Only use granulated salt (max. grain size 5 – 7
mm). Salt tablets are not suitable.
Caution
If the Salt Reservoir Cap is not properly secured,
water and/or chemicals can leak in or out of the
unit causing damage to the warewasher.
7.5
Descaling
You can de-scale the Wash Tank of the warewasher yourself with
the help of the following notes; to de-scale the Rinse Boiler you
will need to contact your service engineer or Classeq.
Warning!
Wear the correct Personal Protective Equipment,
e.g., gloves and goggles, when handling
chemicals and observe all safety notes and
dosing recommendations printed on the
packaging.
Caution
De-scale chemical must not remain in the
warewasher for more than 2 hours.
In order to descale the Wash Tank follow the instructions below:
1.
Remove the chemical tubes from the chemical bottles
and place the ends of the tubes into a container of
water.
2.
Use the commissioning menu to prime the Rinse Aid
and Detergent Pump to draw water all the way into the
warewasher.
3.
Fill and drain the warewasher to remove any chemical
residue.
4.
Refill the warewasher.
5.
Follow the instructions on the chemical packaging to
de-scale the Wash Tank.
6.
Once the de-scale process is complete drain the
warewasher.
7.
Refill and drain the warewasher at least 3 times to
remove any chemical residue.
8.
Refit the chemical tubes to the bottles and prime the
Pumps (►5.4).
9.
Do not overtighten the salt reservoir cap.
warewasher
if there is no salt
21
UK