4.9.1
Preparing the bottles
1.
Remove the cap from the chemical bottle.
2.
Using the drill and 8mm bit, carefully drill a hole in the
centre of the cap.
3.
Feed the tube through the hole.
4.
Fit the bottle weight over the tube and then attach the
end of the tube to a filter.
5.
Feed the filter and bottle weight into the bottle and
screw on the cap.
4.10
Tabling
The warewashers are intended for fixed installation only using
CLASSEQ Tabling fixed to the floor surface and sealed to the unit.
Any other installations must be agreed with and approved by
CLASSEQ. Fit using two fasteners per foot to the floor.
12
Classeq Pass Through Range - User Manual