Technical Data - Balluff BFT Serie Manual De Instrucciones

Ocultar thumbs Ver también para BFT Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Temperature sensor
BFT _ _ _ _-_ _003-_ _ _A0C-_ _
Disassembly
WARNING
Health hazard!
Measuring materials which are irritating, toxic,
carcinogenic, radioactive etc. represent a health hazard.
► Remove all remnants of measuring materials from
the temperature sensor before returning or disposing
of it.
CAUTION
Combustion hazard!
When disassembling there is a risk from escaping
hazardous hot measuring materials.
► Before removing the temperature sensor allow it to
cool sufficiently!
► Remove temperature sensor only when not under
pressure!
Disposal
Medium remnants on the device may result in a hazard to
the operator and the environment. Take appropriate
precautionary measures and dispose of the device
properly.
Observe the national regulations for disposal.
Part label
The part label contains the exact part number and key
technical data for uniquely identifying the device.
Order code
elect. connections
Maximum operating pressure
www.balluff.com
Type code

Technical data

Detection range / measuring range
Measuring element
Limit deviation for the
measuring element per
IEC 60751
Response time per
IEC 60751
Measuring range
Accuracy
Analog signal
Switching output
Display
Setting accuracy
Temperature offset
compensation
Displays
Function displays
Display
Display options
Refresh rate
Pt1000, 2-conductor,
DIN EN 60751 / Class A
Class A
±(0.15 K + 0.002 |t|)
T05 < 5 s; T09 < 10 s
–20...+80 °C
(–4...+176 °F)
≤ ± 0.5 % of span +
temperature sensor error
≤ ± 0.8 % of span +
temperature sensor error
≤ ± (0.8 % of span +
temperature sensor error)
±1 Digit
≤ 0.5 % of span
±3 % of span
LEDs
14-segment display, red,
4-digit, character height 9
mm
Can be rotated
electronically by 180°
200 ms
english
11

Publicidad

Tabla de contenido
loading

Tabla de contenido