The measuring range 0 to 100 vol. % CH
explosive mixtures in the measuring range of 0 to 100 %LEL.
STEL / TWA exposure alarm
Intermittent alarm:
Display » A2 « and »
« (STEL) or »
alternately:
Health hazard! Leave the area immediately. After this alarm, the deployment
of personnel is subject to the relevant national regulations.
– The STEL and TWA alarm cannot be acknowledged or cancelled.
 Switch off the instrument. The values for the exposure evaluation are deleted
after the instrument is switched on again.
The STEL alarm can be triggered with a maximum delay of one minute.
Battery pre-alarm
Intermittent alarm:
Flashing special symbol »
« on the right side of
the display.
Acknowledge pre-alarm:
 Press the [OK] key, only the audible alarm and the vibration alarm are
switched off.
– The battery still lasts approx. 20 minutes after the first battery pre-alarm.
Battery main alarm
Intermittent alarm:
Flashing special symbol »
« on the right side of
the display.
The battery main alarm cannot be acknowledged or cancelled:
– The instrument is automatically switched off again after 10 seconds.
– Before the instrument is switched off, the visual, audible and vibration alarms
are activated for a short time.
WARNING
is not suitable for monitoring
4
« (TWA) and measured value
CAUTION
NOTICE
Instrument alarm
Intermittent alarm:
Special symbol »
« displayed on the right side
of the display:
– The instrument is not ready for operation.
 Contact maintenance or Draeger Service to rectify the problem.

Activating the Info mode

 In measuring mode, press the [OK] key for approx. 3 seconds.
– If any warning or fault messages exist, the corresponding note or error codes
are displayed (see Technical Handbook).
Press the [OK] key successively for the next display. The peak values and
the exposure values TWA and STEV will be displayed.
– If no key is pressed for 10 seconds, the instrument returns automatically to
measuring mode.
Info Off mode
Press the [ + ] key when the instrument is turned off. The name of the gas,
measuring unit, and measuring range limit value are displayed for all channels.
Press the [ + ] key again to exit the Info Off Mode (or via timeout).

Calling the Quick Menu

 In measuring mode, press the [ + ] key three times.
– If functions in the quick menu are activated using the PC software "Dräger CC
Vision", you can select these functions using the [ + ] key. If no functions have
been activated in the quick menu, the instrument remains in measuring mode.
Possible functions:
1. Bump test (configuration for bump test, see
technical manual)
2. Fresh air calibration
3. Delete peak values
4. Display pump information, see technical manual
5. Activate or deactivate pump, see technical manual
 [OK] key to retrieve the retrieve the selected function.
 Press the [ + ]- key to cancel the active function and to switch to measuring
mode.
– If no key is pressed for 60 seconds, the instrument returns automatically to
measuring mode.
21