Disinfection
1. Every two weeks, following the cleaning, you should additionally disinfect only
the following part of the air-conditioner: inside the water tank (5).
2. Use a domestic disinfectant on an alcohol basis or high percentage alcohol for
this purpose. This large-surface disinfectant is an alcohol mixture which you can
buy at any chemist's or drugstore. Both substances are harmless if rinsed off
thoroughly with plenty of water.
3. Wipe all the outer surfaces with a soft, damp cloth.
4. Resume using the air-conditioner as described in the „Instructions for use".
TROUBLESHOOTING
Fault
The air-conditioner does not work
The unit does not work when it is switched on and off
with the ON/OFF key.
Poor cooling performance
Loud noises or vibration
CONDITION OF PURCHASE
As condition of purchase the purchaser assumes responsibility for the correct use and care of this KAZ product according to these operating instructions. The purchaser or
user must himself or herself decide when and for how long this KAZ product is to be in operation.
IMPORTANT: IF PROBLEMS ARISE WITH THIS KAZ PRODUCT, PLEASE OBSERVE THE INSTRUCTIONS IN THE GUARANTEE CONDITIONS. DO NOT ATTEMPT TO OPEN OR REPAIR
THIS KAZ PRODUCT YOURSELF, AS THIS COULD LEAD TO TERMINATION OF THE GUARANTEE AND CAUSE DAMAGE TO PERSONS AND PROPERTY
Technical modifications reserved
Maintenance and storage
1. If you do not wish to use the air-conditioner for a longer period (a week or more),
please clean it as described in the sections „Weekly cleaning" and „Disinfection".
2. Allow the air-conditioner and all its components to dry completely.
3. The air-conditioner must not be stored with a soiled air filter (9), or when there is
water in the water tank (5).
4. Store the air-conditioner standing upright in a cool, dry place.
Possible cause
1.The power plug is not in the power socket.
2. The power socket is faulty.
3. The time set with the timer has not yet elapsed.
1. The water tank light is flashing; the water tank is full.
2. The 3 minutes have not yet elapsed since the unit
was switched off.
3. The room temperature is lower than the
programmed temperature (operating mode COOL).
1. The programmed temperature is too close to the
room temperature.
2. The air filter is blocked.
3. The air-inflow or air-outflow opening is blocked or
covered up.
4. The room is very warm.
5. Doors and/or windows are open.
The unit is not standing on an even surface.
7
Problem solving
1. Plug the power plug into the power socket.
2. Check your fuse box or ask an expert.
3. Wait until the time has elapsed or deactivate the
timer.
1. Empty the water tank.
2. Wait until the 3 minutes have elapsed.
3. Reset the temperature.
1. Pre-select a lower temperature.
2. Cleanse the air filter.
3. Make sure that air-inflow or air-outflow opening is
free.
4. It takes longer for the room to cool down.
5. Close doors and windows.
Stand the unit on an even surface.