3) TRIMMER FuNCTIONS
3.1) TW
If the Encoder device is installed, it assumes the function of regulating anti-crushing sensitivity.
When turned in a clockwise direction, sensitivity is increased.
In the absence of an Encoder device, regulate the maximum duration of opening and closing manoeuvres.
It must be preset approx. 4s more with respect to the actual stroke time of the system.
The adjustment ranges from 3s to 180s maximum.
If the stroke acquisition and slowdowns procedure is executed, the position of the trimmer has no ef-
fect on the operation time.
3.2) TCA
It allows to adjust the automatic closure time.
The adjustment ranges from 3s to 180s maximum.
With TCA trimmer completely turned clockwise, the DL2 LED (green) switches off, TCA is deac-
tivated.
4) DIP-SWITCh FuNCTION
Dip
Function
DIP1
Set-up
DIP2
Multi-flat
PHOT:
DIP3
operating
mode
P.P.: opera-
DIP4
ting mode
Rapid
DIP5
closure
DIP6
Radio
12
Description
To be used only for the setting-up of the torque and the forewarning and braking time. After
moving DIP1 to ON:
- with P1 push-button the torque is adjusted.
- with push-button P2 the forewarning light is activated/deactivated.
- with the Step-by-Step input or a memorised remote control, braking length is adjusted.
See the related sections.
After presetting the parameters, move to OFF.
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function.
The P.P. (Step-by-step) impulse or the impulse of the transmitter have no effect in the opening
phase.
The operating mode of the PHOT input is selected
Off: Input, activated in both opening and closing phases
On: Input, activated in the closing phase only
The operating mode of the "P.P. push-button" and the transmitter are selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation: OPEN > CLOSE > OPEN >
The rapid closure is enabled or disabled with (only with activated TCA)
Off: disabled rapid closure
On: enabled rapid closure. The triggering of the photocell involves, after approx. 3s, the
closure of the door.
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in conjunction with
the Rolling Code HCS transmitters.
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first transmit-
ter sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (self-learning and
dip/switch).