12) TRANSMITTER REMOTE LEARNINg
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out
(without accessing the control unit).
IMPORTANT: The procedure should be carried out with gate in the opening phase, during the
TCA dwell time.
Proceed as follows:
1) Press the hidden key of the transmitter, the code of which has already been stored in memory.
2) Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be
matched to the new transmitter. The flashing light switches on.
3) Within 10 seconds, press the hidden key of the new transmitter.
4) Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at
item 2.
The flashing light switches off.
5) The receiver stores the new transmitter code and exits from the programming mode immediately.
13) LED DIAgNOSTICS
The red LED DL1 indicates the activation of inputs according to the legend hereunder:
The Unit is Powered
STOP
PHOT
SWO
SWC
The green LED DL2 indicates the movement direction of the motor and the status of the gate according
to the legend hereunder:
OPENING
CLOSING
Open gate without TCA
Open gate with TCA
Closed gate
14) FuSES
CORE 230Vac:
F2 = T100mA
CORE 115Vac:
F2 = T200mA
SPECIFICATIONS
Mains power supply
Output, Motor
Motor maximum power
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
flashing slowly
on with fixed light
rapid flashing
1 flash with 2-second interval
2 flashes with 2-second interval
1 blinking per second
2 more than 1 blinking per second
on with fixed light
rapid flash
LED off
F3= F6,3A
F3 = F10A
230 Vac 50/60 Hz (115 Vac 50/60Hz CORE 115)
1 motor, 230 VAC (115VAC CORE 115)
750 W
24Vdc 200mA max.
IP55
-20°C / +50°C
433.92 MHz, incorporated and configurable
(rolling-code or fixed+rolling-code+ ARC Advanced Rolling Code)
64
EN
15