Descargar Imprimir esta página

Important Warning - dirna Bergstrom bycool green line COMPACT ADR Instrucciones De Montaje

Publicidad

Idiomas disponibles

Idiomas disponibles

COMPACT
EN
ALL MODELS EXCEPT EURO 6 - Electric wiring
Take care not to invert polarities when connecting the unit to the power supply. If this were to
happen, the plate would not come on and the unit would not work.
Blower
2,6 Amp.
Az
Blue
N
Black
R
Red
V
Green
B
White
A
Yellow
Na Orange
M
Brown
Compressor
electronic
module

IMPORTANT WARNING!

TEMP
Wiring strip
Na
Electronic
module
10 A. Fuse
-
+
+
F
D
C
P
T
Compressor
ºC
ºF
ON/OFF
Comsuption 30 mAmp.
38
Air conditioning for vehicles
Temperature
probe
NTC 15KΩ a 25º
Fan
2,9 Amp.
PWM.
Compressor
electronic
module
-
+
+
F
D
C
P
T
Compressor