Cleaning The Parts - Oase FiltoClear 3000 Instrucciones De Uso

Ocultar thumbs Ver también para FiltoClear 3000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- English -

Cleaning the parts

(Refer to Unit configuration)
• Clean the container, clamping ring, lid (remove UVC unit head!) including UVC water housing and the meshed tube from
all anlges with a strong water jet.
• If necessary, wash the foam filters individually by vigurously compressing and releasing the filters under running water.
Assembling the foam filters
A. Alternately push the blue (14) and
then the red (13) foam filter onto
the cleaning rods (16), so that the
cleaning rods rest in the two cut-outs.
• Place the fixing disk (15) on the
last foam filter such that the end
collar (44) points to the foam
filters.
B. Fasten the fixing disk on the
cleaning rods using the two screws
(43).
• Reinstate all connections (See
Installation).
Replacing the UVC lamp
Attention! Ultra-violet radiation.
!
Possible consequences: Eye or skin injury from burns
Protective measures:
• Never operate the UVC lamp outside its housing.
• Never operate the UVC lamp in a housing that is defective
Danger: Ultraviolet radiation.
!
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Warning: To reduce the risk of electric shock - Connect only to a circuit that is protected by a ground-fault circuit
interrupter (GFCI)
Attention! Breakable glass
Possible consequences: Injury to your hands caused by cuts
Protective measures: Handle the quartz glass and UVC lamp with care.
Note!
• Condensate forms in the quartz glass tube. This condensate cannot be avoided, however, it does not im-pair
function and safety.
• The quartz glass tube can become scratched or blind over time. In this case, sufficient cleaning performance of the
UVC lamp is no longer guaranteed. The quartz glass tube must be replaced.
• The UVC lamp must be replaced after approx. 8000 operating hours. Only use UVC lamps the designation and
rating of which match the information on the type plate.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
A
B
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Filtoclear 4000Filtoclear 8000

Tabla de contenido