Important - Schulz SRP 3040E Manual De Instrucciones

Compresor a tornillo electronico/analogico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
5.
Air distribution
A 1"
BSP
ball valve is supplied with the compressor for connection to the air distribution network. To maximize
air delivery to point(s) of use, air distribution piping diameter should be no smaller than the air outlet diameter.
Do not use air line filters or regulators whose ports are smaller than the air piping diameter. In smaller systems
it is recommended that an air tank be installed. It should have a minimum storage capacity that is equal to or
th
greater than 1/5 of the capacity (in gallons per minute) of the compressor.
Installing a tank (condensed separator) in this manner will significantly reduce the interval of the demand
fluctuations within the control system of the compressor.
If SRP 3,000 serie compressors are properly sized for a facility, the installation of a tank isn't necessary.
However, a good compressed air network design always includes the installation of a tank in order to cushion
control fluctuations caused by erratic air consumption, gather condensed water and to maintain an adequate
air supply during consumption peaks.
We recommend that the installation, at the compressor's outlet, include an auxiliary air outlet with a hose and
nozzle to clean the cooler and other tasks which may require the use of local compressed air.
For more information and guidance in the design of your air distribution system, please consult your
Authorized - Technical/Distributor.

IMPORTANT

To maintain compressed air quality, do not locate condensed separator, filters or refrigerated dryers in vicinity
of cooling air exhaust stream (See Figure 7 ).
COMMON INDUSTRIAL AIR
1
1.
SCREW COMPRESOR
2.
CONDENSED SEPARATOR
3.
PS 16 ELECTRONIC DRAIN
4.
PRE-FILTER
Note: Installation expenses and accessories are the customer's responsability.
FIGURE 7 - COMPRESSOR'S TYPICAL INSTALLATION WITH ATTACHMENTS FOR COMPRESSED AIR TREATMENT
2
3
5.
AIR DRYER BY REFRIGERATION
6.
POST-FILTER
7.
ACTIVATED CHARCOAL FILTER
(ADSORPTION)
PRE-FILTERED AND DRY
INDUSTRIAL AIR
5
4
Air quality according to ISO 8573.1
Norm Class 1.4.1
REMARK.: For others configurations,
please consult the factory.
Note: Carry out the other components
maintenance, according to their
instruction manuals.
SCHULZ
CLEAN AND DRY
INDUSTRIAL AIR
6
7
43

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Srp 3040

Tabla de contenido