Ce Conformity Declaration - Stanley MasterFix XGrip N08QI Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8.
Trouble shooting
Problem
The tool does not work
Air is coming out of the
safety valve
The trigger does not work
The blind rivet nut
cannot be placed onto the
mandrel
The blind rivet nut is not
set correctly
The tool does not
completely release from
the set rivet nut after trig-
ger is released
The tool does not
perform well
consistently
9.

CE conformity declaration

We hereby declare under our sole responsibilty that these products meet the following
standards and directives:
2006/42/EC
EN 792-1
XGrip N08QI - XGrip N10QI
Cause
The tool has not been connected to the
air connection
The air supply closing valve is still closed
There is insuffi cient air pressure
The air pressure is too high
There is insuffi cient air pressure
The incorrect mandrel/anvil set has been
installed
Stroke is not set correctly
There is insuffi cient air pressure
The capacity of the tool has been
exceeded
Rivet nut has not set
correctly
Requires service
nder our sole responsibilty that these products m
tives:
Mr. Andor Gyurik
Mr. Andor Gyurik
Managing Director
Emhart Teknologies B.V.
Born, The Netherlands: 21-01-2013
Corrective action
Connect the tool to the air
connection
Open the air supply closing valve
Use the correct air pressure 5-7 bar
Use the correct air pressure 5-7 bar
Use the correct air pressure 5-7 bar
Install the correct mandrel/anvil set
Set correct stroke
Use the correct air pressure
Use the correct tool
Push release button
Contact a service centre
5
m
m
eet the follow
w
w
in

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Masterfix xgrip n10qi

Tabla de contenido