Aim at the target. Press the "Measure" button once again
to measure the distance. The result usually appears in
the result line in less than a second and the laser beam
then switches off.
5.489
If further measurements are taken, up to three previously
determined distances are shown in the intermediate result
lines, i.e. a total of the last four measured distances are
shown.
27.317
The tool can, of course, be switched on again at any time
by pressing the "Measure" button. Pressing the C-button
clears all currently displayed values.
6.6.2 Measuring modes
Distances can be measured using two different measur-
ing modes, i.e. single distance measuring or continuous
m
m
m
5.489
12.349
m
24.634
m
m
measuring. Continuous measuring mode is used for set-
ting out given distances or lengths and can also be used
where distance measurement is otherwise difficult, e.g.
at corners, edges or in niches, etc.
6.6.2.1 Single distance measuring ("Measure"
button)
1.
Switch the laser beam on by pressing the "Measure"
button.
2.
Press the "Measure" button again.
The measured distance will be shown in the result
line at the bottom of the display in less than a
second.
6.6.2.2 Single distance measuring ("On /off" button)
1.
Switch the laser beam on by pressing the "On / off"
button.
2.
Press the "Measure" button to switch the laser beam
on and then aim the tool at the target.
3.
Press the "Measure" button again.
The measured distance will be shown in the result
line at the bottom of the display in less than a
second.
6.6.2.3 Continuous measuring (tracking)
NOTE
Continuous measuring is possible in all situations where
individual distances can be measured. This applies also
to functions, such as areas.
1.
Press the "Measure" button for about 2 seconds to
activate the continuous measuring mode.
NOTE When doing so, it doesn't matter whether the
tool or the laser beam is switched on or off. The tool
will always switch to continuous measuring mode.
During continuous measuring, distances are up-
dated in the result line at the rate of approx. 6 - 10
measurements every second. The measuring rate
depends on reflectivity of the target surface. If the
beep signal is active, continuous measuring is in-
dicated by a beep signal approx. 2 - 3 times per
second.
2.
Measuring is stopped by pressing the "Measure"
button once again.
The last valid measurement is then shown in the
result line in the display.
6.6.3 Measuring from corners 3 4
The spike is used when measuring diagonally across
rooms or from inaccessible corners.
1.
Fold out the spike through 180°.
The measuring reference is then set automatically
to the end of the spike. The range meter takes the
extended reference point into account and corrects
the measured distances accordingly.
2.
Position the range meter with the spike at the desired
starting point for the measurement and aim toward
the target.
3.
Press the "Measure" button.
The measured distance is shown in the display.