Troubleshooting
9
Troubleshooting
Problem
Device does not function,
"POWER" LED does not
light up.
CF11, CF26: The device
does not cool (plug is
inserted, "POWER" LED is
lit).
CF11, CF16: The device
does not cool (plug is
inserted, "POWER" LED
flashes, display is empty).
When operating from the
12/24 V socket (DC socket):
The ignition is on, the
device is not working and
the "POWER" LED is not lit.
Pull the plug out of the
socket and make the follow-
ing checks.
CF11: The "ERROR" LED
flashes and the display
shows "ERR1" or "ERR2".
CF16: The display shows
an error message (e.g.
"Err1") and the device does
not cool.
CF26: "ERROR" LED
flashes for longer than 2
minutes, as follows: 3
flashes, pause, 3 flashes,
pause, ...
34
Possible cause
No voltage is flowing
from the DC power
socket in your vehicle.
No voltage present in
the AC voltage
socket.
Defective compressor. This can only be repaired by an author-
The voltage is too low
at the 12/24 V socket.
The DC socket is dirty.
This results in a poor
electrical contact.
The fuse of the 12/24
V plug has blown.
The vehicle fuse has
blown.
Defective device.
The appliance has
switched off due to an
internal fault.
Defective device.
Suggested remedy
The ignition must be switched on in
most vehicles to supply current to the
on-board power socket.
Try using another plug socket.
ised repair centre.
Check the battery and charge if neces-
sary.
Check the cables and connections.
If the plug of your cooler becomes very
warm in the DC socket, either the
socket must be cleaned or the plug has
not been assembled correctly.
Replace the fuse of the 12/24-V plug
(fig. 5 2, page 4).
Replace the vehicle's 12/24 V socket
fuse (usually 15 A). Please refer to the
operating manual of your vehicle.
This can only be repaired by an author-
ised repair centre.
This can only be repaired by an autho-
rised customer service centre.
This can only be repaired by an author-
ised repair centre.