HyTronic Service Handy, Unidirectional
Operation
List of menu items
Urinal controls
Commands
Menu item
Description
[EN]
[DE]
20
Release flush.
[Flush]
Releases a flush.
[Spülung]
21
Check detection range.
[RangeTest]
Red LED in the sensor starts
[TestErfas]
glowing when object enters
detection range. No flush is
released (turns off automatically
after 10 minutes).
22
Block flush.
[BlocFlush]
Command blocks control so
[Blockiere]
that no flush can be released
(10 hours maximum).
23
Empty pipeline.
[EmptyPipe]
Valve is opened and remains
[RohrLeer]
open until command to close is
received (reset after
30 minutes).
24
Factory settings.
[FactrySet]
All settings are restored to
[Werkeinst]
factory settings
Programs
Menu item
Description
[EN]
[DE]
30
Select covered urinal operation.
[CoverOps]
Turns program on or off.
[Deckel-UR]
31
Select interval flush.
[IntFlush]
Urinal control automatically
[IntervSp]
carries out a flush within the set
interval.
22
The functions described in the following may only be set by qualified personnel.
With the HyTronic Service Handy, the menu items listed below can be set
individually. The numbers and terms in the column "Menu item" correspond to what
can be seen on the display of the HyTronic Service Handy. Values are output
through an LED signal in the sensor of the control.
For urinal controls, see "Urinal controls" list.
For washbasin taps, see "Washbasin taps" list.
For WC controls, see "WC controls" list.
For sanitary flushings, see "Sanitary flushings" list.
Application
a) Function test
b) Hygiene
Problems with user detection
a) Carry out service works
b) Deactivate control
a) Service works
b) Winter emptying
Problems concerning the
settings
Application
For the operation of a covered
urinal.
a) Hygiene
b) Flushing out of stagnant
water
Setting range
Factory
setting
Start = "OK"
-
On = "OK"
Off
Off = "OK"
On = "OK"
Off
Off = "OK"
On = "OK"
Off
Off = "OK"
-
-
Setting range
Factory
setting
On = [ON]
Off = [OFF]
Off = [OFF]
2 - 168 hours
Off
0 = Off