HyTronic Service Handy, Unidirectional
Operation

Sanitary flushings

Commands
Menu item
Description
[EN]
[DE]
20
Switch valve 1.
[Valve 1]
Opens the valve and closes it
[Ventil 1]
again on command
21
Switch valve 2.
[Valve 2]
Opens the valve and closes it
[Ventil 2]
again on command
22
Factory settings.
[FactrySet]
All settings are restored to
[Werkeinst]
factory settings
Programs
Menu item
Description
[EN]
[DE]
30
Select operation mode.
[OpsMode]
Choosing between frequent
[BetrModus]
and infrequent flush interval
(see setting 42)
Settings
Menu item
Description
[EN]
[DE]
40
Interval flush - Setting flush time
[IntFlshT1]
V1.
[IntSpZ V1]
41
Interval flush - Set flush time
[IntFlshT2]
V2.
[IntSpZ V2]
42
Interval flush - Set flush interval. -
[IntervalT]
[IntervalZ]
43
Set number of valves.
[SetValves]
[AnzVentil]
28
Application
a) Function test of the valve
b) Flushing out of stagnant
water
c) Winter emptying
a) Function test of the valve
b) Flushing out of stagnant
water
c) Winter emptying
Problems with the settings
Application
Select one of the programs.
Application
-
-
Setting range
Factory
setting
On = "OK"
Off
Off = "OK"
On = "OK"
Off
Off = "OK"
-
-
Setting range
Factory
setting
Frequent = [1]
Frequent [1]
Infrequent = [2]
Setting range
Factory
setting
30 - 999 seconds 180 seconds
30 - 999 seconds 180 seconds
Main menu [1]: 4 -
Main menu [1]:
72 hours
48 hours
Main menu [2]:
Main menu [2]:
48 - 336 hours
168 hours
1 valve = [1]
2 valve [2]
2 valve = [2]