Wc Controls - geberit HyTronic Instrucciones De Uso

Ocultar thumbs Ver también para HyTronic:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
HyTronic Service Handy, Unidirectional
Operation

WC controls

Commands
Menu item
Description
[EN]
[DE]
20
Release the full flush volume.
[FullFlush]
[VollMenge]
21
Release the partial flush
[PartFlush]
volume.
[TeilMenge]
22
Check detection range.
[RangeTest]
Red LED in the sensor starts
[TestErfas]
glowing when an object enters
the detection range. No flush is
released (reset after 10
minutes).
23
Block flush.
[BlocFlush]
Command blocks the control
[Blockiere]
so that no flush can be released
(reset after 10 hours).
24
Factory settings.
[FactrySet]
All settings are restored to
[Werkeinst]
factory settings
Programs
Menu item
Description
[EN]
[DE]
30
Enable manual touchless flush.
[ManFlshEn]
Program enables / disables
[FreiManSp]
manual flush.
31
Select interval flush.
[IntFlush]
The control automatically
[IntervSp]
releases a flush within the set
interval.
32
Select power-on flush.
[PowOnFlsh]
Program activates/deactivates
[NetzEinSp]
flush after power failure.
33
Select pre-flush.
[PreFlush]
Program activates / deactivates
[Vorspülng]
short flush when object enters
detection range.
26
Application
Function test
Function test
Problems with the user
detection
a) Carry out repair works
b) Deactivate control
Problems with the settings
Application
Problems with manual flush
a) Hygiene
b) Flushing out of stagnant
water
c) Drying out of odour trap
a) Function test
b) Hygiene
Hygiene
Setting range
Factory
setting
Start = "OK"
-
Start = "OK"
-
Deactivation = [0]
-
Detection of
person=[1]
Detection of
manual actuation
= [2]
Detection of B-
sensor = [3]
On = "OK"
Off
Off = "OK"
-
-
Setting range
Factory
setting
On = [ON]
On = [ON]
Off = [OFF]
1 - 168 hours
24 hours
168 hours
On = [ON]
Off [OFF]
Off = [OFF]
On = [ON]
Off [OFF]
Off = [OFF]