Settings
Menu item
Description
[EN]
[DE]
40
Set detection time.
[DetectT]
Sets the minimum detection
[VerweilZ]
time that is necessary to
release the flush.
41
Set flush delay.
[DelayTime]
Sets the time between leaving
[Spülverzö]
the detection range and starting
the flush.
42
Set cleaning time.
[CleanTime]
Sets the time during which the
[ReiniZeit]
control is inactive in cleaning
mode.
43
Set the detection distance.
[DetectRng]
[Erfassdis]
Counters
Menu item
Description
[EN]
[DE]
50
Total number of days of operation.
[Days?]
Displays the number of days of operation since commissioning.
[SumBetrT?]
51
Total number of uses.
[Uses?]
Displays the number of uses since commissioning.
[SumBenut?]
52
Total number of flushes / valve switchings.
[Flushes?]
Displays the number of flushes / valve switchings since commissioning.
[SumSpül?]
53
Total number of automatic flushes.
[AutFlush?]
Displays the number of automatic flushes since commissioning.
[SumAutSp?]
54
Total number of manual flushes.
[ManFlush?]
Displays the number of manual flushes since commissioning.
[SumManSp?]
55
Total number of interval flushes.
[IntFlush?]
Displays the number of interval flushes since commissioning.
[SumIntSp?]
56
Total number of pre-flushes.
[PreFlush?]
Displays the number of pre-flushes since commissioning.
[SumVorSp?]
HyTronic Service Handy, Unidirectional
Application
Individual adjustment of the
detection distance
Operation
Setting range
Factory
setting
1 - 60 seconds
7 seconds
1 - 15 seconds
3 seconds
1 - 30 minutes
10 minutes
Short = [0]
Short [0]
Long = [1]
Output
Days
Uses
Flushes / switchings
Flushes
Flushes
Flushes