HyTronic Service Handy, Unidirectional
Operation
Washbasin taps
Commands
Menu item
Description
[EN]
[DE]
20
Switch valve.
[Valve]
Flushes until turned off (closes
[Ventil]
automatically after 10 minutes).
21
Check detection range.
[RangeTest]
Red LED in the sensor starts
[TestErfas]
glowing when object enters
detection range. No flush is
released (turns off automatically
after 90 seconds).
22
Factory settings.
[FactrySet]
All settings are restored to
[Werkeinst]
factory settings
Programs
Menu item
Description
[EN]
[DE]
30
Select main menu.
[MainProgr]
Attendance: Flushes as long as
[Hauptmenü]
an object is in the detection
range.
Singapore: Water turns off after
3 seconds.
Settings
Menu item
Description
[EN]
[DE]
40
Set run-on time.
[RunOnTime]
Tap keeps on flushing
[NachlaufZ]
according to entered value after
an object has left the detection
range.
41
Set safety time.
[SafetyT]
Limiting flow duration
[AbschaltZ]
42
Set sensor beams.
[SensorOps]
[Sensoren]
24
Application
a) Function test of the valve
b) Flushing out of stagnant
water
Problems with the user
detection
Problems with the settings
Application
Select one of the two
programs.
Application
a) Hygiene
b) Cleaning of implements
Safety switch-off function
Improving detection
Setting range
Factory
setting
On = "OK"
Off
Off = "OK"
On = "OK"
Off
Off = "OK"
-
-
Setting range
Factory
setting
Attendance =
Attendance
[OFF]
Singapore = [ON]
Setting range
Factory
setting
0 - 2 seconds
0 seconds
40 seconds = [4]
40 seconds
50 seconds = [5]
[4]
60 seconds = [6]
Both on = [0]
Both on [0]
Lower on = [1]
Upper on = [2]