6.6 AFTER OPERATION

• Clean (par. 7.4).
• Move all the controls forward 
and back a few times.
• Make sure the choke is engaged.
• Check there are no loose or damaged 
components. If necessary, replace 
the damaged components and tighten 
any screws and loose bolts.
Do not cover the machine when the
engine and the exhaust are still warm.
7. MAINTENANCE
7.1
GENERAL INFORMATION
IMPORTANT The safety regulations to
follow during machine use are described in
par. 2.4. Strictly comply with these instructions
to avoid serious risks or hazards.
All service and all maintenance
checks must be carried out on a
stationary machine with the engine
switched off. Before cleaning or doing
maintenance work, take out the ignition
key and read the relevant instructions.
Wear adequate clothing,
gloves and goggles before carrying
out any maintenance.
• The frequency and types of maintenance 
are summarised in the "Maintenance 
Table". The table will help you maintain 
your machine's safety and performance. 
It summarises the main interventions to 
be made and the frequency applicable 
to each of them. Carry out the relevant 
intervention according to the first deadline.
• The use of non-genuine spare parts and
accessories could adversely affect machine 
operation and safety. The manufacturer 
shall decline all liability in the event of 
injuries or damages caused by such parts.
• Genuine spare parts are supplied
by authorized assistance 
workshops and dealers.
IMPORTANT All the maintenance and
adjustment operations not described
herein must be carried out by your dealer
or Authorised Service Centre.
7.2 REFUELLING
To refuel:
1. Unscrew the tank closure cap 
and remove it (fig. 10.F).
2. Insert the funnel (fig. 10.G).
3. Refuel and remove the funnel (fig. 10.G).
4. Close the fuel cap securely after refuelling 
and clean away any spills (fig. 10.F).
NOTE Do not fill the fuel tank right to the top.
NOTE Only use the fuel indicated in the data
table. Do not use other types of fuel. It is possible
to use ecological fuels, i.e. alkylate petrol. The
composition of this petrol is less harmful to
people and the environment. No negative effects
linked to use of the same have been reported.
However, there are types of alkylate-based
petrol available on the market for which it is not
possible to give precise indications regarding
their use. For further information it is advisable
to consult the instructions and data provided
by the producer of the alkylate-based petrol.
NOTE Fuel is perishable and should not remain
in the tank for more than 30 days. Before storing
for a long period, fill the tank with a sufficient
amount of fuel to reach final destination (chap. 8).
7.3 CHECK/TOP-UP ENGINE OIL
Always check the oil level before use.
NOTE The machine is delivered
to the client without engine oil.
7.3.1 Check/top-up
Procedure:
• Position the machine on a level 
surface for the check.
• Wipe around the dipstick. Unscrew it and 
pull it out. Clean the dipstick (fig.10.H).
• Push the dipstick down completely 
without screwing it into place.
• Now pull the dipstick up again. 
Read off the oil level.
• Top up using the oil extension hose (fig.3.E) if
the level is lower than the "MAX" mark (fig.12)
• For the correct replacement 
procedure, see par. 7.3.2
Do not overfill as this could cause
the engine to overheat. If the oil level
exceeds the "MAX" mark, the oil must be
drained until the correct level is achieved.