SATA air star C Instrucciones De Servicio página 49

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Instructions for use and maintenance SATA air star C
9. Markings
All parts essential for functioning can be identified by means of their part number. Exhalation
membranes and mask body are furthermore marked with the date of manufacture.
The diaphragm features a marking containing figures and dots - example: 98 and 3 dots
means: 1998 plus 3 years is production year 2001. The mask body also has a date clock with
year indication. The arrow indicates the month.
The CE marking is located on the inside of the mask body and is supplemented by the
number 0158, which indicates the authorised authority Deutsche Montan Technologie GmbH,
Zertifizierungstelle für Atemschutz, Am Technologie Park 1 D-45307 Essen, Germany, which
carried out the CE-certification and also takes on the production supervision according to
para 11A of the Directive 89/686/CE.
Below the CE marking is the reference to the European standard EN140:1998, which is
mandatory for fulfilment of the CE certification.
10. Repairs
Defective or worn out parts must be immediately replaced, but only if the operating instruc-
tions list the item concerned as a spare part. Otherwise, the respirator must be returned
for repair.
Warning: If spare parts are required, only use original spare parts from SATA.
The membrane of the exhalation valve is removable. The inhaling valve can be drawn over
the plastic pin of the connecting piece. Ensure that the valve membrane is not torn when
it is returned. A performance and leakage test must be completed after parts that influence
the air-tightness of the half mask have been exchanged. The respirator will only function
safely if the activated charcoal cartridge has been correctly and completely inserted in the
filter case.
11. Components/Spare parts/Accessories
Please find the spare parts at the gatefold page at the end of this brochure.
Art. No.
Product description
3194
Adsorber glass
13623
SATA quick coupling G 1/4 a
13656
Nipple for SATA quick coupling
13870
Air hose 1,2 m
13904
Filter cartridge for respirators
13920
Respirator belt with buckle
22947
O-ring 54 x 2,5 mm
25015
Gauge for adsorber
25106
Spindle, cpl.
49080
Safety compressed air supply
hose 9,5 x 5 mm, 6 m long
49726
Protective cage f. respirator filter
53934
Safety quick coupling
53942
Nipple G 1/4
58941
Belt unit without adsorber
Art. No. without illustration
97485
SATA protect Protective googles
Please note: The head straps must be replaced completely. There are no single compo-
nents available.
Art. No.
Product description
75176
Safety quick closure coupling
92296
SATA combi fine filter unit 444
120469
Compressed air hose mask,cpl.
120477
Distributor (pack of 2 pcs.)
122085
Connection piece
(pack of 2 pcs.)
122341
Belt unit with T-piece
134254
Headbands + Holder frame
+ Mask cap
134270
5 x Exhalation diaphragm
+ 10 x Inhalation diaphragm
134965
Half-mask respiratory protection
cleaner
137588
Half mask