Behaviour of the press device when the battery is empty:
When a pressing operation begins, a check is made to determine whether the battery charge is
EN
sufficient to complete the pressing operation. If this is not the case the device does not start. The
green LED (2) flashes.
If the green LED (2) flashes following a pressing operation, the pressing operation was carried out
correctly. The battery must be recharged prior to the next pressing operation
Pos : 44 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/1a - Quetsc hgefahr Fing er ACO102, AC O152 @ 0\mod_1382615425260_18.doc x @ 1540 @ 12 @ 1
8
Commissioning and operation
8.1 Preparing the ACO102
Pos : 45 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/2 - Ger ätesc haden d. Hal tebolzen ACO102, AC O152, ACO202XL, ECO301, AF P/EFP202 @ 0\mod_1382615981245_18.doc x @ 1553 @ @ 1
Pos : 46 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/4 - Info D auer betrieb ACO102, AC O152, ACO/EC O202, ACO202XL, EC O301, AF P/EFP202 @ 0\mod_1382617729764_18.doc x @ 1565 @ @ 1
Pos : 47 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/5a - Ei ns etz en - AC O102, AC O152, @ 0\mod_1385644275462_18.doc x @ 1590 @ @ 1
Pos : 48 /RVT/Allgemeines /#### Seitenumbr uch #### @ 0\mod_1380200837280_0.doc x @ 885 @ @ 1
CAUTION!
Fingers risk being crushed if the device is operated without a press jaw
(Fig. 4)
If no press jaw is fitted, fingers could be placed in the at-risk zone. Fingers could be
crushed when the device is started.
Therefore:
–
Do not operate the device without the press jaws.
–
Keep your fingers away from the at-risk zone.
CAUTION!
Not locking the retaining pin (8) fully can cause damage to the device.
(Fig. 5 to 7).
If the retaining pin (8) is not fully inserted and locked, the cylinder can break during the
pressing operation.
Therefore:
–
Press in retaining pin (8) as far as it will go and turn 180° to the rear.
Information!
The press device is not suitable for continuous operation. Following 30 minutes
of continuous operation, a short break of at least 15 minutes must be taken to
allow the device to cool down.
•
Insert the press jaw into the press device as shown in Fig. 5 to 7.
16