2.
Observe the system manufacturer's instructions when fitting the press jaws. (Fig. 8)
Pos : 62 /RVT/Inbetri ebnahme und Betrieb/Ver press en/07 - Info Pr ess bac ke AC O102, ACO152, AC O/ECO202, AFP/EF P202 @ 0\mod_1386668397015_18.doc x @ 1700 @ @ 1
EN
Pos : 63 /RVT/Inbetri ebnahme und Betrieb/Ver press en/09a - Punkt 3 AC O102, AC O152, ACO/ECO202, ACO202XL, AF P/EF P202 @ 0\mod_1386672196372_18.doc x @ 1712 @ @ 1
3.
To start the process, press the start button.
Pos : 64 /RVT/Inbetri ebnahme und Betrieb/Ver press en/10a - Punkt 4 AC O102, AC O152 @ 0\mod_1386672370698_18.doc x @ 1718 @ @ 1
4.
When the pressing operation has been completed:
Pos : 66 /RVT/R einigung, Wartung, R eparatur /01a - Vorsic ht - Einsc halter- ACO102, ACO152, AC O202XL, ACO401, AXI/AAP102 @ 0\mod_1390815867244_18.doc x @ 1770 @ 1 @ 1
9
Cleaning, maintenance and repair
Pos : 67 /RVT/R einigung, Wartung, R eparatur /02 - Ser vic eans chrift - AC O102, AC O152, ACO/EC O202, ACO202XL, EC O301, AC O401, AFP/EF P202, AXI/AAP102 @ 0\mod_1391000010165_18.doc x @ 1790 @ @ 1
Service addresses
Novopress GmbH & Co. KG
Scharnhorststr. 1
41460 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting Novopress or at
www.novopress.de.
Pos : 68 /RVT/R einigung, Wartung, R eparatur /03a - Informati on Wartung - AC O102, ACO152, ACO/ECO202, AC O202XL @ 0\mod_1391004569271_18.doc x @ 1796 @ @ 1
Service intervals
Service and repair work may only be carried out by Novopress or the authorised Novopress specialist
workshops.
Pos : 69 /RVT/R einigung, Wartung, R eparatur /04a - R egel mäßig 1.ter T eil - ACO102, AC O152, ACO/EC O202, AF P/EFP202 @ 0\mod_1391080694964_18.doc x @ 1820 @ @ 1
Routine inspection (before use, at the start of the working day) and when soiled (Fig. 11)
Check for visible damage, material cracks and other signs of wear. If defects are found, do not use the
device and have it repaired.
Pos : 70 /RVT/R einigung, Wartung, R eparatur /05 - H albj ährlic h - ACO102, AC O152, ACO/EC O202, ACO202XL, ECO301, AC O401, AF P/EF P202 @ 0\mod_1392970870376_18.doc x @ 1846 @ @ 1
•
Six-monthly inspection
Have the device inspected by a qualified electrician or a Novopress workshop
Pos : 71 /RVT/R einigung, Wartung, R eparatur /06 - J ährlich - ACO102, ACO152, AC O/EC O202, AC O202XL, ECO301, AC O401, AF P/EFP202, EF P203 @ 0\mod_1392975314209_18.doc x @ 1852 @ @ 1
•
Annually to get a 1-year extended warranty (see section 11 Warranty and guarantee)
Have the press device inspected and serviced at Novopress or a Novopress workshop.
Pos : 72 /RVT/Allgemeines /#### Seitenumbr uch #### @ 0\mod_1380200837280_0.doc x @ 885 @ @ 1
Information!
Make sure that the press jaw is fully closed when pressing is complete (Fig. 9).
•
Detach the press jaw from the press fitting (Fig. 10).
CAUTION!
Risk of injury during cleaning or repair work from inadvertently pressing
the On switch.
Therefore:
–
Comply with the safety instructions and always remove the battery before
performing cleaning, servicing or repair work.
Information!
The next service deadline is indicated on the press device.
This service must be performed at least every 2 years or at the latest when the LED
display indicates that a service is due (see Section 8.2 Meaning of the LED display).
18