43
Features Menu (Continued)
4. To change a setting, press the Left and Right arrows to select which digit to modify, then use the
Up and Down arrows to change the selected digit.
5. When you are done, press the Enter button to shave the changes. To cancel any changes, press the
Escape button to exit mode without saving.
Wave and Pulse Operation
The Wave and Pulse Features operate in conjunction with Features 1-9, and must be linked (See page 35)
to any of those features in order to operate. If the Wave or Pulse feature is linked to Feature 1 or 2, then
the operation of these features is controlled through the Feature 1 and Feature 2 buttons.
1. Press the Feature 1 or Feature 2 button, then press the Start/Stop button. IntelliFlo will activate
the feature and the active feature LED will be lit until the feature has finished operation. The
Wave or the Pulse feature will activate at the same time, and continue to operate for as long
Feature 1 or 2 operates.
2. The "Feature 1" screen will display a countdown of the time remaining in the duration you
programmed for that feature. By using the Up and Down arrow buttons, you can switch between
screens displaying current flow, power usage in Watts (W), and pump speed in RPM.
If the Wave or Pulse feature is linked to Feature 3-9, then the feature functions as part of the filter cyles
programmed in the Filter settings menu, and IntelliFlo must be in Filter Mode for Wave or Pulse to
operate. IntelliFlo will activate the Wave or Pulse feature whenver it activates the feature to which it is
linked. For example, if the Pulse Feature is linked to Feature 3 and Feature 3 is programmed to start at
15:00, the Pulse feature will activate at 15:00 in conjunction with Feature 3, and will continue to operate
for as long Feature 3 operates. If Feature 3-9 is disabled, the Wave or Pulse feature linked to it will not
operate.
Like Features 3-9 and M.O. Flo, Wave and Pulse may be enabled or disabled in the "Activation" Setting
(See page 35). If Enabled is selected in the Wave or Pulse "Activation" setting (See "Wave and Pulse
Setup" on page 35) , the feature will start and stop whenever the feature it is linked to starts and stops. If
Disabled is selected in the Wave or Pulse "Activation" setting, or if the feature to which Wave or Pulse is
linked is itself disabled, IntelliFlo will not run the feature.
IntelliFlo VF Installation and User's Guide