Battery change in the manual transmitter (O, P):
Improper handling can lead to damage to the manual transmitter!
Touch a bare metal surface (e.g. a radiator) to discharge static charges, which could lead to damage to the
internal components of the manual transmitter!
Ensure that neither dirt nor moisture can enter the manual transmitter!
− Guide a slot screwdriver (30) into the lateral opening (31) of the manual transmitter.
− Open the manual transmitter housing by slightly turning the screwdriver, then remove the housing bottom secti-
on (32).
− Pull the battery (33) out of the holder (34).
− Push the new battery into the holder (34). Ensure that the embossed side (35) of the battery points upward.
Pos: 83 /Alle Produkte/Überschriften/H1 Lagern / Überwintern @ 7\mod_1196625251745_121.doc @ 41495
Storage/Over-wintering
Pos: 84 /Lampen/Wasserspieltechnik/Water-Trio/Quintet/Lagern und Überwintern Water Trio/Quintet @ 8\mod_1223632685324_121.doc @ 54230
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the Water Trio / Water Quintet frost protected and submersed in a water filled container. Do not immerse the
plug.
Pos: 85 /Alle Produkte/Entsorgung - gem. Bestimmungen/Fachhändler @ 0\mod_1125578523312_121.doc @ 1407
Disposal
Dispose of the unit in accordance with the national legal regulations.
Pos: 86 /Alle Produkte/Überschriften/H1 Störungsbeseitigung @ 7\mod_1196625290699_121.doc @ 41521

Remedy of faults

Pos: 87 /Lampen/Wasserspieltechnik/Water-Trio/Quintet/Störungstabelle Water Trio/Quintet @ 8\mod_1223376103151_121.doc @ 54083
Malfunction
Pumps do not start
Unit does not respond to manual transmitter
Insufficient fountain height
Unit switches off after a brief running time
(approx. 10 s)
Pos: 88 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630
Cause
No mains voltage
Manual transmitter not taught in
Impeller blocked or soiled
Pump strainer casing soiled
Nozzles soiled
Water temperature too high
Pumps run dry
Remedy
Check mains voltage
Check supply lines
Teach-in manual transmitter
Clean impeller
Clean strainer casing
Clean nozzles
Note maximum water temperature of + 35°C.
For switching on again, pull the power plug and
reinsert in the socket.
Check water level and, if necessary, top up the
water. For switching on again, pull the power
plug and reinsert in the socket.