Before starting the machine for the first time, check that:
•
the mains voltage is the same as the voltage on the CE
plate;
•
the electric connections have been made using cables
of proper cross-section,
•
the (wall) main power switch has suitable fuses;
•
the oil level is over the minimum level - top up with the
same type of oil if necessary;
CONNECT THE TANK WITH A HOSE.
Only specialised technicians can start the compressor
for the first time.
AM x-10 F1 Micro
ROTAR MICRO SE (fig.4):
Before starting up the machine remove the rear panel, switch
on the machine by positioning switch (2) in the ON position
and check the correct rotating direction of the motor, as
indicated by the arrows applied on the screw-motor plate (fig.6).
If the rotating direction is not correct, immediately switch off the
machine taking both the switch (2) and the wall switch to the
OFF position.
Open the electric compartment and invert the position of the
electric cables of the two phases in the powering terminal
board.
Close the electric compartment and restart.
ROTAR MICRO TA (fig.5): Premendo il tasto START (1) si
avvia la procedura di accensione.
The turning on procedure starts by pressing the START
key (1).
The Stand-by led (7) blinks and after a few seconds the
presence of the phases and their correct sequence is
checked, if the compressor blocks and the warning light
turns on the phase sequence device has intervened, press
the RESET key (2) and bring the wall switch to OFF position.
Open the electric compartment and invert the position of two
phases in the power terminal box. Close the electrical
compartment and restart.
The start up procedure is repeated: the Screw led (6) blinks
and after a few seconds it becomes fixed, the load phase
starts until the "set loadless pressure" value is reached.
The Screw led (6) blinks again and the loadless operation
phase begins.
If at the end of the loadless operation (default 75 sec.) the
pressure has not fallen below the "set load pressure" value
the compressor stops and the Stand-by led turns on (7);
otherwise upon reaching the "set load pressure" value the
compressor restarts the loading phase and the Screw led
turns on in fixed mode (6).
During normal function, press the Function key (3). The
following information will be displayed:
pressure,
temperature,
total hours of operation (with compressor on),
hours of operation loaded (with compressor in load phase).
By pressing the RESET key (2) the turn off procedure starts,
the Screw led (6) blinks and the compressor enters the
loadless operation mode for the time set by the parameter
"delayed stop time" (default 60 sec.). At the end of the cycle
the compressor stops.
ALARMS
ON
3
Rotar Micro - Cod.197CC2300 - Rev.01 - 07/2008
5
10
15
0
OFF
8
8
8
8
8
4
6
AIR
STAND-BY
START
STOP
5
7
GB
4
1
2
3
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
1
2
6
11
11
11
11
11