Close cock B and withdraw the hose.
Refill with new oil using hole A (quantity for complete
refilling: 2.2 litres) and refit the plug.
Start up the compressor and allow to function for 5
minutes, and then shut it down. Discharge all of the air and
wait 5 minutes before controlling the oil level. Top up, if
necessary.
THE EXHAUSTED OIL IS HIGHLY POLLUTANT! For its
disposal comply with the current laws on environmental
protection.
The first equipment oil is: RotEnergy Plus.
In the case of changing the type of oil, operate only for the
complete replacement. NEVER MIX DIFFERENT TYPES OF
OIL.
In this case, change also the oil filter and the separator
filter.
CHECKING THE TRANSMISSION BELT
TENSION (Fig.10)
When the compressor is stopped, remove the rear panel
and check the belt tension.
Use a suitable measuring instrument that determines with
precision the belt tension degree by means of a frequency
measuring device in order to perform this control.
Operate as follows:
Place the microphone of the measuring instrument near to the belt (about half way) and hit the belt with a wrench.
Read the value detected by the instrument and if different from the values indicated in the table (fig.10A), adjust the
tension:
Value higher = belt too tight
Value lower = belt too loose
Adjust by loosening the four bolts and adjust the tension with screw C2.
After adjusting, tighten the bolts C1.
Check the frequency value again and if necessary, repeat the operation.
REPLACING THE TRANSMISSION BELT (Fig.10)
When the compressor is stopped, remove the rear panel. Loosen the four bolts C1 and act on screw C2 loosening
belt C until completely loose.
Remove the belt and replace it with a new one.
After replacing, check the belt tension as described previously.
REPLACING THE MINIMUM VALVE (Fig.11)
Replace the seals highlighted with the letter F.
REPLACING THE FLEXIBLE HOSES
It is recommended that they are replaced when changing
the oil.
Loosen the hose fittings, replace them and tighten with
force the fittings. Continue with the final phases of the oil
changing procedure.
14
14
14
14
14
Rotar Micro - Cod.197CC2300 - Rev.01 - 07/2008
MAINTENANCE
C2
C
C1
COMPRESSOR
AM 2-10 F1 Micro
MICRO 5
AM 3-10 F1 Micro
MICRO 5
MICRO 5
MICRO 4
MICRO 4
MICRO 3
MICRO 3
PRESSURE
BELT TENSION
10 bar
85 Hz
08 BAR
94 Hz
10 bar
91 Hz
10 BAR
97 Hz
13 BAR
102 Hz
08 BAR
88 Hz
10 BAR
91 Hz
08 BAR
83 Hz
10 BAR
85 Hz